Form Number TM61310 
Rev 2 Aug 2007 
Page 6 
Physical and Environmental Characteristics 
Characteristics Description 
Dimensions (H×W×D) 
150mm(H) ×76mm (W) ×38mm(D) (with holster)
5.9” (H) x 3.0”(W) x1.5”(D) 
Weight (with battery& holster) 
0.219Kg (7.1 oz.) 
Environmental characteristics 
Description 
Temperature operating range 
0 to +40°C 
Non-Operating 
-20 to +60°C <80% R.H. 
Humidity (operating) 
<75% R.H. 
Altitude 
6561.7 Ft. (2000m) 
Indoor Use 
Indoor Use 
 
Certifications and compliances 
Safety
 
Complies with UL 61010B-1 
Input Safety Rating 
V / Ω/Temp/mA, UL 61010B-1, UL 61010-B-2-031, EU 
61010-1 EN61010-2-031, Cat II 600Volts 
CAT 
III
: Distribution level mains, fixed installation. 
CAT 
II
: Local level mains, appliances, portable equipment 
 
CAT 
I
: Signal level, special equipment or parts of equipment, 
telecommunication, electronics. 
Pollution Degree 2 
Do not operate in environments where conductive 
Pollutants may be present. 
EC Declaration 
of Conformity 
Meets the intent of Directive 89/336/EEC for Electromagnetic 
Compatibility and Low Voltage Directive 73/23/EEC for product 
safety. Compliance was demonstrated to the following specifications 
as listed in the official Journal of the European Communities: 
En 55011 Class A: Radiated and Conducted Emissions. 
En 50082-1 Immunity: 
              IEC 801-2 Electrostatic Discharge 
              IEC 801-3 RF Radiated 
En 61010-1    Safety requirements for electrical equipment for 
             measurement, control, and laboratory use.