Справочник Пользователя для Panasonic AJ-spd850E
52
Setup menus (continued)
No./Item
Description
USER menu <TIME CODE>
500
VITC BLANK
This selects whether to output the
VITC signal at the positions selected
by setup menu items No. 501 (VITC
POS-1) and No. 502 (VITC POS-2).
VITC signal at the positions selected
by setup menu items No. 501 (VITC
POS-1) and No. 502 (VITC POS-2).
0000 BLANK :
VITC signals are not output.
0001
THRU :
VITC signals are output.
501
VITC POS-1
This sets the position where the VITC
signal is to be inserted.
signal is to be inserted.
Note:
The same line as the one used for the
setup menu items No. 502 (VITC POS-2)
and No. 662 (UMID POS) setting cannot
be set.
The same line as the one used for the
setup menu items No. 502 (VITC POS-2)
and No. 662 (UMID POS) setting cannot
be set.
[625i system]
0000
0000
7L
:
:
0004
11L
:
:
0015
22L
[525i system]
0000
0000
10L
:
:
0006
16L
:
:
0010
20L
502
VITC POS-2
This sets the position where the VITC
signal is to be inserted.
signal is to be inserted.
Note:
The same line as the one used for the
setup menu items No. 501 (VITC POS-1)
and No. 662(UMID POS) setting cannot
be set.
The same line as the one used for the
setup menu items No. 501 (VITC POS-1)
and No. 662(UMID POS) setting cannot
be set.
[625i system]
0000
0000
7L
:
:
0006
13L
:
:
0015
22L
[525i system]
0000
0000
10L
:
:
0008
18L
:
:
0010
20L
503
TCG REGEN
This selects the signal to be
regenerated when the time code
generator (TCG) in the REGEN mode.
regenerated when the time code
generator (TCG) in the REGEN mode.
0000 TC&UB :
Both the time code and user bit are
regenerated.
regenerated.
0001
TC :
Only the time code is regenerated.
0002
UB :
Only the user bit is regenerated.
505
EXT TC SEL
This selects the time code to be used
when an external time code is to be
used.
when an external time code is to be
used.
0000 LTC :
The LTC of the TIME CODE IN
connector is used.
0001 VITC :
The VITC of the input video signal is used.
Note:
During recording, there is a discrepancy
in the picture and superimposed TC
value displayed, but the actual recording
is not adversely affected in any way.
The LTC of the TIME CODE IN
connector is used.
0001 VITC :
The VITC of the input video signal is used.
Note:
During recording, there is a discrepancy
in the picture and superimposed TC
value displayed, but the actual recording
is not adversely affected in any way.
No./Item
Description
506
BINARY GP
This sets the usage status of the user
bit of the time code generated by the
TCG.
bit of the time code generated by the
TCG.
0000 000 :
NOT SPECIFIED (character set not
specified)
specified)
0001 001 :
ISO CHARACTER (8 bits character
set based on ISO646, ISO2022)
set based on ISO646, ISO2022)
0002 010 : UNASSIGNED 1 (undefined)
0003 011 : UNASSIGNED 2 (undefined)
0004 100 : UNASSIGNED 3 (undefined)
0005 101 : PAGE/LINE
0006 110 : UNASSIGNED 4 (undefined)
0007 111 : UNASSIGNED 5 (undefined)
0003 011 : UNASSIGNED 2 (undefined)
0004 100 : UNASSIGNED 3 (undefined)
0005 101 : PAGE/LINE
0006 110 : UNASSIGNED 4 (undefined)
0007 111 : UNASSIGNED 5 (undefined)
507
PHASE CORR
This selects whether to control the
phase correction of the LTC which is
output from the TIME CODE OUT
connector.
phase correction of the LTC which is
output from the TIME CODE OUT
connector.
0000 OFF :
Phase correction control is not
performed.
performed.
0001
ON :
Phase correction control is performed.
508
TCG CF FLAG
This selects whether the CF flag of
the TCG is to ON.
the TCG is to ON.
0000 OFF : CF flag is OFF.
0001
0001
ON : CF flag is ON.
509
DF MODE
This selects the DF or NDF mode for
CTL and TCG.
CTL and TCG.
0000
DF :
The drop frame mode is used.
0001 NDF :
The non-drop frame mode is used.
Notes:
• Drop frame mode is valid only when the
• Drop frame mode is valid only when the
REMOTE button is lit or the setup menu
No. 001 (LOCAL ENA) is set to ENA.
No. 001 (LOCAL ENA) is set to ENA.
• This menu option is not displayed in the
625i system.
The underlined items indicates the initial setting.