Справочник Пользователя для Panasonic AWRP120GJ

Скачать
Страница из 60
13
Operating preset memory (PMEM)
The preset memory of a remote camera can be operated from the unit.
The following settings that you have adjusted in advance can be stored 
in preset memory.
 
z
Pan/tilt positions
 
z
Zoom positions
 
z
Focus positions
 
z
Lens iris settings (manual iris only)
 
z
White balance settings
 
z
If the MEM ENABLE button indicator is off, preset memory 
operation is not possible. Press the button to turn on its indicator 
and then perform operation.
 
z
Preset numbers PMEM 1 to 10 are also used as start positions 
when recalling tracing memory. Preset data may be overwritten or 
deleted by tracing memory operation.
 
z
The number of preset memory and data that can be registered 
differ depending on the remote camera.  
For details, check the operating instructions for the corresponding 
model.
Notes
PMEM button
Number buttons  
[1] to [50]
PMEM PAGE  
button
PMEM PAGE  
indicators
MEM SETTING button
MEM DELETE button
MEM STORE button
MEM ENABLE button
 
z
Changing pages
Press one of the number buttons [1] to [50] to directly select any of the 
50 preset memory.
Furthermore, pressing the PMEM PAGE button to change pages allows 
you to operate up to 100 preset memory for each camera.
Press the PMEM  
PAGE button
Page 1 selected
Page 2 selected
Button indicator on
Button indicator on
<Preset numbers and registered pages>
Preset number
Page number Number button
PMEM 1 to PMEM 50
Page 1
[1] to [50]
PMEM 51 to PMEM 100
Page 2
Example: When specifying preset number “PMEM 51”
1. Press the PMEM page button to select Page 2.
2. Press number button [1].
 
z
Lighting of number button indicators
The lighting method of the number buttons differs depending on the 
remote camera or pan-tilt head that the unit is controlling.
<Lighting method of number button indicators>
Remote cameras and 
pan‑tilt heads
Lighting method of number button 
indicators
AW-HE50, AW-HE60, 
AW-HE120
The indicators of the number buttons with 
preset memory registered turn on.
AW-HE100, AW-PH360, 
AW-PH405, AW-PH650, 
AW-PH400
The indicator of the number button that 
was last pressed turns on.
However, when preset memory is deleted 
in DELETE mode, all of the number 
buttons turn off.