Справочник Пользователя для Panasonic AWRP120GJ

Скачать
Страница из 60
43
Control interface for external devices
 
„
TALLY/GPI (JST: JBY‑25S‑1A3F(LF)(SN))
13
1
25
14
Pin number
Signal name
Description of signal
Operation
1
TALLY IN 1
TALLY IN1 to TALLY IN10 tally inputs
⇒ “Tally settings” (page 39)
Contact input
(Status operation)
14
TALLY IN 2
2
TALLY IN 3
15
TALLY IN 4
3
TALLY IN 5
16
TALLY IN 6
4
TALLY IN 7
17
TALLY IN 8
5
TALLY IN 9
18
TALLY IN 10
6
GND
GND
19
GPI IN 1
Calling of PMEM GROUP1 to PMEM GROUP4
⇒ “Operating preset memory groups (PMEM 
GROUP)” (page 16)
Contact input
(Trigger operation)
 
z
Trigger width 
 30 msec
7
GPI IN 2
20
GPI IN 3
8
GPI IN 4
21
GPI IN 5
Control of the ENABLE BUTTON settings
⇒ “Configuring the unit operation settings” (page 27)
9
GPI IN 6
Control of MENU CONTROL settings
⇒ “Configuring the unit operation settings” (page 27)
22
GND
GND
10
GPI OUT 1
Remote camera selection 0
*
Open collector output
(Status operation)
23
GPI OUT 2
Remote camera selection 1
*
11
GPI OUT 3
Remote camera selection 2
*
24
GPI OUT 4
Remote camera selection 3
*
12
GPI OUT 5
Alarm
25
GND
GND
13
NC
GND
GPI OUT
Example of GPI OUT connection
Ensure that the conditions given below 
are satisfied.
Withstand voltage: Max. 24 V DC
Current: Max. 50 mA
AW‑RP120
(Max . current 50 mA)
(Max . voltage 24 V)
Example of TALLY IN and GPI IN connections
Provide contact inputs.
GND
GPI IN
TALLY IN
+3.3 V
AW‑RP120
 For the cameras registered to the “1. CAM OUT1” to “10. CAM OUT10” items in GPI OUT menu [45], the 
selection states on the unit can be output to GPI OUT1 to GPI OUT4.
<Output states of GPI OUT1 to GPI OUT4 when the camera number registered to CAM OUT is 
selected>
Output of GPI OUT1 to GPI OUT4
GPI OUT1
GPI OUT2
GPI OUT3
GPI OUT4
CAM OUT1
On
Off
Off
Off
CAM OUT2
Off
On
Off
Off
CAM OUT3
On
On
Off
Off
CAM OUT4
Off
Off
On
Off
CAM OUT5
On
Off
On
Off
CAM OUT6
Off
On
On
Off
CAM OUT7
On
On
On
Off
CAM OUT8
Off
Off
Off
On
CAM OUT9
On
Off
Off
On
CAM OUT10
Off
On
Off
On