Page 40
Epson Research and Development
Vancouver Design Center
S1D13708
Programming Notes and Examples
X39A-G-003-01
Issue Date: 01/11/20
ADVANCE
D
 IN
FOR
MAT
ION
Subje
ct to C
ha
nge
Note
Truncate all fractional values before writing to the address registers.
Note
SwivelView 0° and 180° require the PIP
+
 width to be a multiple of 32 
÷ 
bits-per-pixel. 
SwivelView 90° and 270° require the PIP
height to be a multiple of 32 
÷ 
bits-per-pixel. 
If this is not possible, refer to Section 8.4, “Limitations” .
PIP
+
 Line Address Offset
The PIP
+
 Line Address Offset register indicates the number of dwords per line in the PIP
+
 
window image.
The image width must be a multiple of 32 
÷
 bpp. If the image width is not such a multiple, 
a slightly larger width must be chosen (see Section 8.4, “Limitations” ).
PIP
+
 width and PIP
+
 height refer to the PIP
+
 dimensions as seen in SwivelView 0° 
(landscape mode). Stride is the number of bytes required for one line of the image; the 
offset register represents the stride in DWORD steps.
PIP
+
 Stride = image width 
×
 bpp 
÷
 8
For SwivelView 0° and 180°,
PIP
+
 Width=((REG[8Dh],REG[8Ch]) - (REG[85h],REG[84h]) + 1) 
×
 (32 
÷
 bpp)
PIP
+
 Height=(REG[91h],REG[90h]) - (REG[89h],REG[88h]) + 1
For SwivelView 90° and 270°,
PIP
+
 Width=((REG[91h],REG[90h]) - (REG[89h],REG[88h]) + 1) 
×
 (32 
÷
 bpp)
PIP
+
 Height=(REG[8Dh],REG[8Ch]) - (REG[85h],REG[84h]) + 1
Note
Image width can be larger than PIP
+
 width (or PIP
height, for SwivelView 90° or 
270°).
PIP
+
 Window Line Address Offset Register 0
REG[80h]
Read/Write
PIP
+
 Window Line Address Offset Bits 7-0
7
6
5
4
3
2
1
0
PIP
+
 Window Line Address Offset Register 1
REG[81h]
Read/Write
n/a
PIP
+
 Window Line Address 
Offset Bits 9-8
7
6
5
4
3
2
1
0