Intel® Server Boards S5520HC and S5500HCV TPS 
Intel® Light Guided Diagnostics 
Revision 1.2 
   
Intel order number E39529-009 
121
 
8. Intel
®
 Light Guided Diagnostics 
Both server boards have several onboard diagnostic LEDs to assist in troubleshooting board-
level issues. This section provides a description of the location and function of each LED on the 
server boards. 
8.1 5-volt 
Stand-by 
LED 
Several server management features of these server boards require a 5-V stand-by voltage 
supplied from the power supply. The features and components that require this voltage must be 
present when the system is “power-down” include the Integrated BMC, onboard NICs, and 
optional Intel
®
 RMM3 installed in the Intel
®
 RMM3 slot.  
The LED is located near the Intel
®
 SAS Entry RAID Module AXX4SASMOD slot in the lower-left 
corner of the server boards and is labeled “5VSB_LED”. It is illuminated when AC power is 
applied to the platform and 5-V stand-by voltage is supplied to the server board by the power 
supply. 
 
Figure 48. 5-volt Stand-by Status LED Location