Intel® Light Guided Diagnostics 
Intel® Server Board S5520HC / S5500HCV TPS 
 
  
Revision 
1.2 
Intel order number E39529-009 
124 
 
By issuing the appropriate hex IPMI “Chassis Identify” value, the ID LED will either blink 
nlue for 15 seconds and turn off or will blink indefinitely until the appropriate hex IPMI 
Chassis Identify value is issue to turn it off.  
 
The bi-color (green / amber) System Status LED operates as follows: 
Table 69. System Status LED 
Color State 
Criticality 
Description 
Green 
Solid on 
System OK 
System booted and ready.  
Green Blink 
 
Degraded 
System degraded 
– 
Non-critical temperature threshold asserted 
– 
Non-critical voltage threshold asserted 
– 
Non-critical fan threshold asserted 
– 
Fan redundancy lost, sufficient system cooling maintained. 
This does not apply to non-redundant systems. 
– 
Power supply predictive failure 
– 
Power supply redundancy lost. This does not apply to non-
redundant systems. 
– 
Correctable errors over a threshold of 10 and migrating to 
a mirrored DIMM (memory mirroring). This indicates the 
user no longer has spare DIMMs indicating a redundancy 
lost condition. The corresponding DIMM LED should light 
up. 
Amber Blink 
Non-critical 
Non-fatal alarm – system is likely to fail: 
– 
Critical temperature threshold asserted 
– 
CATERR asserted 
– 
Critical voltage threshold asserted 
– 
VRD hot asserted 
– 
SMI Timeout asserted 
Amber Solid 
on 
Critical, non-
recoverable 
Fatal alarm – system has failed or shut down 
– 
CPU Missing 
– 
Thermal Trip asserted 
– 
Non-recoverable temperature threshold asserted 
– 
Non-recoverable voltage threshold asserted 
– 
Power fault / Power Control Failure 
– 
Fan redundancy lost, insufficient system cooling. This 
does not apply to non-redundant systems. 
– 
Power supply redundancy lost insufficient system power. 
This does not apply to non-redundant systems. 
Note:
 This state also occurs when AC power is first applied to 
the system. This indicates the BMC is booting. 
Off N/A 
Not 
ready 
– 
AC power off, if no degraded, non-critical, critical, or non-
recoverable conditions exist. 
– 
System is powered down or S5 states, if no degraded, 
non-critical, critical, or non-recoverable conditions exist. 
* When the server is powered down (transitions to the DC-off state or S5), the BMC is still on standby power and 
retains the sensor and front panel status LED state established before the power-down event. If the system status is 
normal when the system is powered down (the LED is in a solid green state), the system status LED is off.