Intel® Server Board S5520HC / S5500HCV TPS
 
Appendix C: BMC Sensor Tables 
Revision 1.2 
   
Intel order number E39529-009 
153
Table 81. Integrated BMC Core Sensors 
Full Sensor Name 
(Sensor name in SDR) 
Sensor 
Platform 
Applicability 
Sensor Type 
Event / 
Reading 
Type 
Event Offset 
Triggers 
Contrib. To 
System 
Status 
Assert / 
De-
assert 
Readabl
 Value / 
Offsets 
Event 
Data 
Rearm 
Stand-
by 
00 - Power down 
04 - A/C lost 
OK 
Power Unit Status 
(Pwr Unit Status) 
01h All 
Power Unit 
09h 
Sensor 
Specific 
6Fh 
05 - Soft power 
control failure 
06 - Power unit 
failure  
Fatal 
As and 
De 
– Trig 
Offset A  X 
00 - Fully 
Redundant 
OK 
01 - Redundancy 
lost 
Degraded 
02 - Redundancy 
degraded 
Degraded 
03 - Non-
redundant: 
sufficient 
resources. 
Transition from 
full redundant 
state. 
Degraded 
04 – Non-
redundant: 
sufficient 
resources. 
Transition from 
insufficient state. 
Degraded 
Power Unit Redundancy1 
(Pwr Unit Redund) 
02h 
Chassis-
specific 
Power Unit 
09h 
Generic 
0Bh 
05 - Non-
redundant: 
insufficient 
resources 
Fatal 
As and 
De 
– Trig 
Offset A  X