Справочник Пользователя для Honeywell VISTA-128BP

Скачать
Страница из 80
 
 
– 50 – 
Using #70 Relay Menu Mode 
General Information 
Your system may be set up so that certain lights or other devices can be 
turned on or off by using the #70 command from either a keypad or a 
telephone keypad (if 4286 VIP module is used). Ask your installer if this has 
been done in your system. 
To activate relays from a keypad, enter 4-digit security code + [#] +70. 
Follow the keypad prompts described below. 
To activate relays using a telephone and 4286 VIP module, first dial 
the 2-digit phone access code. When the system acknowledges the access, 
enter 4-digit security code + [#] + 70. The following prompts/voice responses 
will begin. 
ENTER DEVICE NO. 
00=QUIT 01 
Voice: "ENTER DEVICE CODE NOW" 
Enter the 2-digit number of the device to be 
activated. 
Note that if an invalid number is entered, the 
system will simply ask you to reenter the number. 
NN    DEVICE IS OFF 
HIT  0=OFF ,  1=ON 
Voice: "voice descriptor DEVICE nn ON/OFF.  FOR 
voice descriptor ON ENTER 1, FOR voice descriptor 
OFF ENTER 0" 
Press 0 or 1 to turn the device off or on respectively. 
"nn" represents the 2-digit device number and voice 
descriptor
 is the relay voice descriptor programmed 
by the installer. 
NN    DEVICE IS OFF 
HIT THE "
✴" KEY 
Voice: "voice descriptor DEVICE nn ON/OFF.  TO 
EXIT ENTER 00 NOW" 
From a keypad, press 
✴ to continue. The ENTER 
DEVICE NO. prompt will appear. 
From a telephone keypad, enter 00 to exit, or 
enter the next relay number to be programmed. The 
current on/off state of that relay will be 
annunciated as described above. Alternatively, if 6 
seconds elapses with no key depression, the 4286 
VIP module will annunciate the "ENTER DEVICE 
CODE NOW" message.