Справочник Пользователя для First Alert FA168CPS

Скачать
Страница из 16
– 2 – 
TO ENTER PROGRAMMING MODE: 
Local programming requires the use of an alpha keypad connected to the keypad terminals on the control. 
A.  POWER UP, then depress [
] and [#]  both at once, within 50 seconds of powering up (if ✱98 was used to exit program 
mode, this method must be used to reenter program mode). 
 OR 
B. Initially, key: Installer Code (4 + 1 + 1 + 2) plus 8 + 0 + 0. 
 
DATA FIELD PROGRAMMING PROCEDURES 
Task Procedure 
Go to a Data Field 
Press [
∗] + [Field Number], followed by the required entry.  
Entering Data 
When the desired field number appears, simply make the required entry. When the last entry for a 
field is entered, the keypad beeps three times and automatically displays the next data field in 
sequence. 
If the number of digits that you need to enter in a data field is less than the maximum digits available 
(for example, the phone number fields *41, *42), enter the desired data, then press [
∗ ] to end the 
entry. The next data field number is displayed. 
Review a Data Field  Press [#] + [Field Number].  
Data will be displayed for that field number. No changes will be accepted in this mode. 
Deleting an Entry Press 
[
∗] + [Field Number] + [∗]. (Applies only to fields ∗40 thru *46, *94, and pager programming 
fields) 
 
INTERACTIVE MODE PROGRAMMING (
56, 57, 58, 79, 80, 81, 82, 187) 
Press [
] + [Interactive Mode No.] (for example, ✱56). The alpha display keypad will display the first of a series of prompts 
requesting entries.  
Interactive Mode 
Used to Program 
✱56 Zone Programming 
Zone characteristics, report codes, alpha descriptors, and serial numbers for 5800 RF 
transmitters. 
✱57 Function Key Programming  Unlabeled keypad keys (known as ABCD keys) for special functions 
✱58 Zone Programming 
Same options as *56 mode, but with fewer prompts. Intended for those familiar with  
(Expert mode) 
this type of programming, otherwise *56 mode is recommended. 
✱79 Output Device Mapping 
Assign module addresses and map individual relays/powerline carrier devices 
✱80 Output Programming 
4229 or 4204 Relay modules, Powerline Carrier devices, or on-board triggers 
✱81 Zone List Programming 
Zone Lists for relay/powerline carrier activation, chime zones, pager zones, etc. 
✱82 Alpha Programming 
Zone alpha descriptors 
 
INITIALIZE DOWNLOAD and RESET DEFAULTS 
96  Initializes download ID and subscriber account number. 
97  Sets all data fields to original factory default values. 
 
TO EXIT PROGRAMMING MODE: 
98  Exits programming mode and prevents  re-entry by:  Installer Code 8 + 0 + 0.  If ✱98 is used to exit programming 
mode, system must be powered down, and method A above used to enter the programming mode. 
 
See field *88 for other *98 Program mode lockout options. 
 
99  Exits programming mode and allows  re-entry by: Installer Code + 8 + 0 or method 1 above. 
 
Special Messages 
OC = OPEN CIRCUIT (no communication between Keypad and Control). 
EE or ENTRY ERROR = ERROR (invalid field number entered;  re-enter valid field number). 
After powering up, AC, dI (disabled) or Busy Standby and NOT READY will be displayed after approximately 4 seconds. 
This will revert to a “Ready” message in approximately 1 minute, which allows PIRS, etc. to stabilize. You can bypass this 
delay by pressing [#] + [0].  
If E4 or E8 appears, more zones than the expansion units can handle have been programmed. The display will clear after 
you correct the programming.