6 - 20 
6   MOTION SFC PROGRAMS 
 
6.9.3 Parallel branch, parallel coupling  
(1)   Parallel branch  
Multiple routes connected in parallel are executed simultaneously. Each parallel 
branch destination may be started by either a step or a transition.  
 
G1
G255
F10
K2
K3
F1
Max. number of parallel branches = 255
G1
G2
G3
G255
G1
G0
 
After operation completion of 
preceding step, steps K2 to 
F10 connected in parallel are 
executed when the completion 
of condition set at transition 
G0. Thereafter, routes are 
executed simultaneously up to 
parallel coupling point.  
 
POINT 
 
"Shift" or "WAIT" can be set to a transition preceding a parallel branch.  
"WAITON" and "WAITOFF" cannot be set.  
 
(2)   Parallel coupling  
A parallel branch must be coupled by a parallel coupling. A jump setting to 
another branch route can be made within parallel branch-parallel coupling.  
In this case, a jump destination is a midway parallel coupling point (coupling 
jump).  
You cannot set a jump to exit from within parallel branch-parallel coupling.  
 
PAB1
PAE1
G1
K2
ON M100
K3
G3
K100
K5
K4
F10
G11
F11
G12
F12
Parallel branch point
Coupling jump
Parallel coupling point
After the servo program K3 has 
completed stopping, execution waits 
until the completion of condition set 
at transition G3 and servo program  
K4 completes starting. 
On completion of waiting, execution 