Справочник Пользователя для Mitsubishi Electronics A171SHCPUN

Скачать
Страница из 161
1. SPECIFICATIONS OF MOTION SYSTEM COMPONENTS
 3
1.2 Overall Configuration of Motion System
1.2.1 A172SHCPUN/A171SHCPUN System Overall Configuration
Motion slot
Sequence module slot
Manual pulse generator/
synchronous encoder
interface module
L
im
it switch
ou
tp
ut
 mo
du
le
Battery
Emergency stop input
A1S input module or
special function module
Extension cable
(A1SC    B for 
A1S6    B 
and A168B)
(A1S    NB
for A6    B)
Po
we
r s
u
p
p
ly
mo
dul
e
Main base unit(A178B-S1/A17    B)
IBM PC
(DOS)
Manual pulse generator   1
(MR-HDP01)
Teaching unit
A31TU-E/A30TU-E
External input signals
SSC I/F card/board
(A30CD-PCF/A30BD-PCF)
Electromagnetic brake command output
SSCNET cable
Termination
resistance
A6BAT
100/200VAC
Motion CPU
A172
SENC
A1S
Y42
P
E
Serial absolute synchronous encoder cable
(MR-HSCBL   M)
Serial absolute synchronous encoder    1
(MR-HENC)
TRA tracking
FLS upper stroke limit
RLS lower stroke limit
STOP signal
DOG/CHANGE near-zero point dog/
changeover between speed and position
8
1
RS422
RS422
IBM PC (DOS,Windows)
SSCNET2
SSCNET1
d1
d2
d3
dn
M
E
M
E
M
E
M
E
MR-H-BN/MR-J2S-B/MR-J2-B model
Servo amplifier
*2
*2:n:No. of control axes (max.)
A171SHCPUN   4
A172SHCPUN   8
A171SHCPUN A172SHCPUN
4
1
Sequence extension base
   Up to one extension base unit for A1S6   B
   Up to one extension base unit for A168B
   (GOT compatible)
   Up to one extension base unit for A6   B
GOT
*1
*1:No. of motion slots
A17    B              1
A178B-S1          2
Communication cable
(A270CDCBL    M/
 A270BDCBL    M)
SSCNET:Servo System Controller NETwork
POINTS
(1) When using the sequence extension base and bus connection type GOT, select the A168B as the
sequence extension base. When not using the sequence extension base, you can connect the bus
connection type GOT directly to the extension connector of the main base unit.
(2) When using a teaching unit A31TU-E with a dead-man switch, a dedicated connecting cable
A31TUCBL03M is required between the CPU unit and A31TU-E connector.  If the A31TU-E is
connected directly to the RS422 connector of the CPU without using a dedicated cable, the
A31TU-E will not operate at all. After disconnecting the A31TU-E, attach a short-circuit connector
A31SHORTCON for A31TUCBL.
(3) In a motion module, a sequence A1S I/O modules can also be installed.
(4) Though the external input signals of A172SENC are reserved for eight axes, for A171SHCPUN,
set those for the first half four axes (PX0 to PX0F).