Chapter 5    Data Used for Positioning Control
 
5.1.8 Setting items for condition data 
When carrying out "high-level positioning control" or using the JUMP instruction in the 
"major positioning control", the "condition data" must be set as required. The setting 
items for the "condition data" are shown below. 
Up to 10 "condition data" items can be set for each axis. 
Refer to Chapter 10 "High-Level Positioning Control" for details on the "high-level 
positioning control", and to Section 5.5 "List of condition data" for details on each 
setting item. 
 
Control 
 
 
 
Condition data 
Major positioning 
control 
High-level positioning control 
Other than 
JUMP 
instruction 
JUMP 
instruction
Block start
(Normal 
start ) 
Condition 
start 
Wait start
Simul-
taneous 
start 
Repeated 
start 
(FOR 
loop) 
Repeated 
start 
(FOR 
condition)
[Da.15] Condition target 
– 
 
– 
 
 
 
– 
 
[Da.16] Condition operator 
– 
 
– 
 
 
 
– 
 
[Da.17] Address 
– 
 
– 
 
 
– –   
[Da.18] Parameter 1 
– 
 
– 
 
 
 
– 
 
[Da.19] Parameter 2 
– 
 
– 
 
 
 
– 
 
[Da.23]
 
Number of 
simultaneously 
starting axes 
QD77MS16
 
– – – – –   
– – 
[Da.24]
 
Simultaneously 
starting axis No.1 
QD77MS16
 
– – – – –   
– – 
[Da.25]
 
Simultaneously 
starting axis No.2 
QD77MS16
 
– – – – –   
– – 
[Da.26]
 
Simultaneously 
starting axis No.3 
QD77MS16
 
– – – – –   
– – 
 
 
 :  Set as required ("–" when not required) 
 
 :  Setting limited 
 
–  :  Setting not required (The setting value is invalid. When the value is the default value or within the setting range, there is no 
problem.) 
 
 
  Checking the condition data 
 
[Da.15] to [Da.19], [Da.23] to [Da.26] are checked with the following timing. 
 
  When "Block start data" starts 
  When "JUMP instruction" starts