Справочник Пользователя для Mitsubishi Electronics QD77MS16

Скачать
Страница из 1038
 
 
8 - 19 
Chapter 8  OPR Control 
 
8.4 Selection of the OPR setting condition 
8.4.1 Outline of the OPR setting condition 
If executing the home position return (OPR) when selecting "0: Need to pass servo 
motor Z-phase after power on" with "Function selection C-4 (PC17)", it is necessary 
that the servomotor has been rotated more than one revolution and passed the Z 
phase (Motor reference position signal) and that the zero point pass signal ([Md.108] 
Servo status (low-order buffer memory address): b0) has turned ON. 
When selecting "1: Not need to pass servo motor Z-phase after power on" with 
"Function selection C-4 (PC17)", it is possible to turn the zero point pass signal 
([Md.108] Servo status (low-order buffer memory address): b0) ON without passing the 
zero point. 
 
 
Buffer memory address (low-order) 
QD77MS2/QD77MS4 
QD77MS16 
[Md.108] Servo status: b0 
876+100n 2476+100n 
 
n: Axis No.-1 
 
 Data setting 
 
To select the "OPR setting condition", set the "servo amplifier" shown in the 
following table. 
Servo parameters are set for each axis. 
 
The "OPR setting condition" is stored into the following buffer memory addresses.   
 
Setting item 
Setting 
value 
Setting details 
Buffer memory address 
QD77MS2 
QD77MS4 
QD77MS16
Function selection C-4 
(PC17) 
0 : Need to pass servo motor Z-phase after 
power on 
1 : Not need to pass servo motor Z-phase 
after power on 
30180+200n 28480+100n
 
n: Axis No.-1 
: Refer to Section 5.2.8 "Servo parameters" for information on the storage details. 
 
  Precautions during operation 
 
(1)  Set "Function selection C-4 (PC17)" (transferred the parameter to the servo 
amplifier from the Simple Motion module), and then turn off the power supply 
of the servo amplifier once and
 
switch it on again to make that parameter 
setting valid.