Справочник Пользователя для Mitsubishi Electronics QD77MS16

Скачать
Страница из 1038
 
 
9 - 54 
Chapter 9    Major Positioning Control 
 
POINTS 
 
 When the movement amount is converted to the actual number of command 
pulses, a fraction appears after the decimal point, according to the movement 
amount per pulse. This fraction is normally retained in the Simple Motion module 
and reflected at the next positioning. 
For the fixed-feed control, since the movement distance is maintained constant (= 
the command number of pulses is maintained constant), the control is carried out 
after the fraction pulse is cleared to zero at start. 
 
[Accumulation/cutoff for fractional pulses] 
 
When movement amount per pulse is 1.0 [
m] and movement for 2.5 [m] is 
executed two times. 
 
 Conversion to command pulses: 2.5 [m] ÷ 1.0 = 2.5 [PLS] 
 
2PLS
2PLS
2PLS
3PLS(=2.5+0.5)
Movement
amount
0.5 PLS hold by the Simple Motion
module is carried to next positioning.
INC Linear 1
Fixed-feed 1
0.5 PLS hold by the Simple Motion
module is cleared to 0 at start and
not carried to next positioning.
2.5   m
2.5   m
 
 
 When the "reference axis speed" is set during 2-axis fixed-feed control, set so the 
major axis side becomes the reference axis. If the minor axis side is set as the 
reference axis, the major axis side speed may exceed the "[Pr.8] Speed limit 
value". 
 
 
9.2.8 3-axis fixed-feed control (interpolation) 
In "3-axis fixed-feed control" ("[Da.2] Control system" = fixed-feed 3), three motors are 
used to carry out fixed-feed control in a linear path while carrying out interpolation for 
the axis directions set in each axis.   
In fixed-feed control, any remainder of below control accuracy is rounded down to 
convert the movement amount designated in the positioning data into the command 
value to servo amplifier. 
(Refer to Section 9.1.6 "Interpolation control" for details on interpolation control.)