Chapter 9    Major Positioning Control 
 
9.2.18 Position-speed switching control 
In "position-speed switching control" ("[Da.2] Control system" = Forward run: 
position/speed, Reverse run: position/speed), before the position-speed switching 
signal is input, position control is carried out for the movement amount set in "[Da.6] 
Positioning address/movement amount" in the axis direction in which the positioning 
data has been set. When the position-speed switching signal is input, the position 
control is carried out by continuously outputting the pulses for the speed set in "[Da.8] 
Command speed" until the input of a stop command. 
The two types of position-speed switching control are "Forward run: position/speed" in 
which the control starts in the forward run direction, and "Reverse run: position/speed" 
in which control starts in the reverse run direction. 
 
  Switching over from position control to speed control 
 
(1)  The control is selected the switching method from position control to speed 
control by the setting value of "[Cd.45] Speed-position switching device 
selection". 
 
Setting item 
Setting 
value 
Setting details 
Buffer memory address 
QD77MS2 
QD77MS4 
QD77MS16 
[Cd.45] 
Speed-
position 
switching 
device 
selection 
 
The device used for speed-
position switching is selected. 
0: Use the external command 
signal for switching from 
position control to speed 
control 
1: Use the near-point signal for 
switching from position control 
to speed control 
2: Use the "[Cd.46] Speed-
position switching command" 
for switching from position 
control to speed control 
1566+100n 4366+100n 
 
The switching is performed by using the following device when "2" is set. 
 
Setting item 
Setting 
value 
Setting details 
Buffer memory address 
QD77MS2 
QD77MS4 
QD77MS16 
[Cd.46] 
Speed-
position 
switching 
command
 
The speed-position control 
switching is performed when "2" 
is set in "[Cd.45] Speed-position 
switching device selection". 
1567+100n 4367+100n