10 - 16 
Chapter 10  High-Level Positioning Control 
 
10.4 Setting the condition data 
10.4.1 Relation between various controls and the condition data 
"Condition data" is set in the following cases. 
 
(1)  When setting conditions during execution of Section 9.2.21 "JUMP instruction" 
(major positioning control)   
(2)  WHEN SETTING conditions during execution of "high-level positioning control" 
 
The "condition data" to be set includes the setting items from [Da.15] to [Da.19] and 
[Da.23] to [Da.26], but the setting requirements and details differ according to the 
control system and setting conditions.   
 
The following shows the "condition data" "[Da.15] Condition target" corresponding to 
the different types of control. 
(The "condition data" settings in this chapter are assumed to be carried out using   
GX Works2.) 
 
Control type
 
[Da.15] 
Setting item 
High-level positioning control 
Major positioning 
control 
Block 
start 
Wait 
start 
Simultaneous 
start 
Repeated start 
(For condition) 
JUMP instruction
01: Device X 
(Note-1)
 
 
02: Device Y 
(Note-1)
 
 
03: Buffer memory   
(1 word) 
 
 
 
 
 
04: Buffer memory   
(2 words) 
 
 
 
 
 
05: Positioning data 
No. 
 
 
 
 
 
 
 : One of the setting items must be set. 
 : Setting not possible 
(Note-1): Refer to devices X/Y which belongs to Simple Motion module. 
 
REMARK 
It is recommended that the "condition data" be set whenever possible with   
GX Works2. Execution by sequence program uses many sequence programs and 
devices. The execution becomes complicated, and the scan times will increase.