Справочник Пользователя для Mitsubishi Electronics QD77MS16

Скачать
Страница из 1038
 
 
10 - 21 
Chapter 10  High-Level Positioning Control 
 
10.5 Multiple axes simultaneous start control 
The "multiple axes simultaneous start" starts outputting the command to the specified 
simultaneous starting axis at the same timing as the started axis. 
The maximum of four axes can be started simultaneously. 
 
[1]  Control details 
The multiple axes simultaneous start control is carried out by setting the 
simultaneous start setting data to the multiple axes simultaneous start control 
buffer memory of the axis control data, "9004" to "[Cd.3] Positioning
 start No.
" of 
the start axis, and then turning ON the positioning start signal. 
• QD77MS2 ........... Set the start data No. of simultaneous starting axis 
(positioning data No. to be started simultaneously for each 
axis) in "[Cd.30] Simultaneous starting axis start data No. 
(axis 1 start data No.)" and "[Cd.31] Simultaneous starting 
axis start data No. (axis 2 start data No.)".   
• QD77MS4 ........... Set the start data No. of simultaneous starting axis 
(positioning data No. to be started simultaneously for each 
axis) in "[Cd.30] Simultaneous starting axis start data No. 
(axis 1 start data No.)" to "[Cd.33] Simultaneous starting axis 
start data No. (axis 4 start data No.)".   
• QD77MS16 ......... Set the number of axes to be started simultaneously and axis 
No. in "[Cd.43] Simultaneous starting axis", and the start data 
No. of simultaneous starting axis (positioning data No. to be 
started simultaneously for each axis) in "[Cd.30] 
Simultaneous starting own axis start data No." and "[Cd.31] 
Simultaneous starting axis start data No.1" to "[Cd.33] 
Simultaneous starting axis start data No.3". 
 
[2]  Restrictions 
(1) The error "Error before simultaneous start" (error code: 501) will occur and 
all simultaneously started axes will not start if the simultaneously started axis 
start data No. is not set to the axis control data on the start axis or set outside 
the setting range. 
(2) The error "Error before simultaneous start" (error code: 501) will occur and 
all simultaneously started axes will not start if either of the simultaneously 
started axes is BUSY. 
(3) The error "Error before simultaneous start" (error code: 501) will occur and 
all simultaneously started axes will not start if an error occurs during the 
analysis of the positioning data on the simultaneously started axes. 
(4) No error or warning will occur if only the start axis is the simultaneously 
started axis. 
(5) This function cannot be used with the sub function Section 13.7.7 "Pre-
reading start function".