Справочник Пользователя для Mitsubishi Electronics QD77MS16

Скачать
Страница из 1038
 
 
13 - 24 
Chapter 13  Control Sub Functions
 
13.4.2 Torque limit function 
The "torque limit function" limits the generated torque to a value within the "torque limit 
value" setting range when the torque generated in the servomotor exceeds the "torque 
limit value".   
The "torque limit function" protects the deceleration function, limits the power of the 
operation pressing against the stopper, etc. It controls the operation so that 
unnecessary force is not applied to the load and machine.   
 
The details shown below explain about the "torque limit function".   
  [1] Relation between the torque limit function and various controls 
 [2] Control details 
  [3] Precautions during control 
  [4] Setting the torque limit function 
 
[1]    Relation between the torque limit function and various controls 
The following table shows the relation of the "torque limit function" and various 
controls.  
 
Control type 
Torque limit 
function 
Torque limit value * 
OPR 
control 
Machine OPR control 
 
"[Pr.17] Torque limit setting 
value" or "[Cd.101] Torque 
output setting value". 
: After the "[Pr.47] Creep 
speed" is reached, this value 
becomes the "[Pr.54] OPR 
torque limit value". 
Fast OPR control 
"[Pr.17] Torque limit setting 
value" or "[Cd.101] Torque 
output setting value". 
Major 
positioning 
control 
Position 
control 
1-axis linear control 
2 to 4-axes linear 
interpolation control 
 
1-axis fixed-feed control 
2 to 4-axes fixed-feed 
control (interpolation) 
 
2-axis circular interpolation 
control 
 
1 to 4-axes speed control 
Speed-position switching control 
Position-speed switching control 
 
Other 
control 
Current value changing 
– 
Setting value is invalid. 
JUMP instruction, NOP 
instruction, LOOP to LEND
– 
Manual 
control 
JOG operation, Inching operation 
"[Pr.17] Torque limit setting 
value" or "[Cd.101] Torque 
output setting value". 
Manual pulse generator operation 
 
Expansion 
control 
Speed-torque control 
 
Torque limit value before 
switching control mode is 
continued. 
 
  :  Set when required (Set to " – " when not used.) 
–  :  Setting not required (The setting value is invalid. Use the initial value or a value 
within the setting range.) 
  :  Shows the torque limit value when "[Cd.22] New torque value/forward new torque 