Справочник Пользователя для Mitsubishi Electronics QD77MS16

Скачать
Страница из 1038
 
 
13 - 100 
Chapter 13  Control Sub Functions
 
13.7.10 Speed control 10 x multiplier setting for degree axis function 
The "Speed control 10 x multiplier setting for degree axis function" is provided to 
execute the positioning control by 10 x speed of the setting value in the command 
speed and the speed limit value when the setting unit is "degree". 
 
This section explains the "speed control 10 multiplier specifying function for degree 
axis" as follows: 
 [1] Control details 
  [2] Setting method of "Speed control 10 x multiplier setting for degree axis function" 
 
[1]  Control details 
 
When "Speed control 10 multiplier specifying function for degree axis" is valid, 
this function related to the command speed, monitor data, speed limit value, is 
shown below. 
(1) Command speed 
(a) Parameters 
  "[Pr.7] Bias speed at start" 
  "[Pr.46] OPR speed" 
  "[Pr.47] Creep speed" 
  "[Cd.14] New speed value" 
  "[Cd.17] JOG speed" 
  "[Cd.25] Position-speed switching control speed change register" 
  "[Cd.28] Target position change value (New speed)" 
  "[Cd.140] Command speed at speed control mode" 
 "[Da.8] Command speed" 
(b) Major positioning control 
1) For "2 to 4 axis linear interpolation control" and "2 to 4 axis fixed-feed 
control", the positioning control is performed at decuple speed of 
command speed, when "[Pr.83] Speed control 10 x multiplier setting for 
degree axis" of reference axis is valid.   
2) For "2 to 4 axis speed control", "[Pr.83] Speed control 10 x multiplier 
setting for degree axis" is evaluated whether it is valid for each axis.   
If valid, the positioning control will be performed at decuple speed of 
command speed.