Справочник Пользователя для Mitsubishi Electronics QD77MS16

Скачать
Страница из 1038
 
 
16 - 54 
Chapter 16  Troubleshooting
 
16.5 List of warnings 
The following table shows the warning details and remedies to be taken when a 
warning occurs. 
16.5.1 QD77MS detection warning 
Classification 
of warnings 
Warning 
code 
Warning name 
Warning 
Operation status at warning occurrence
 
 
 
— 000 
(Normal 
status) 
— 
— 
 
Common 
warnings 
100 
Start during operation 
• The start request is issued while the axis 
is BUSY. 
• Positioning was started during speed 
control mode/torque control mode. 
Position control mode: 
The operation continues. 
Speed control mode/torque control mode:
The operation continues. (Positioning 
start is not executed.) 
 
 
 
 
 
104 
Restart not possible 
The restart command is issued when the 
axis operation status is not "Stopped". 
Continue the operation. 
 
 
 
 
109 
Teaching in BUSY 
The teaching request is issued while the 
axis is BUSY. 
The warning is issued for the axis 
designated at the time of the teaching 
request. 
 
 
 
 
110 
Less than minimum 
speed 
The overridden speed becomes “0”. 
The system is controlled with the currently 
executing unit of 1. 
 
 
111 
In PLC READY 
The request for writing to the flash ROM is 
issued when the PLC READY is turned 
ON. 
The warning for axis 1 is issued. 
 
 
 
112 
Illegal override value 
A value other than 1 to 300 is set for the 
override value. 
• When a setting value is 0:   
Controlled at 100. 
• When a setting value is 301 or more:   
Controlled at 300.   
 
 
 
 
113 
Outside new torque 
value range/outside 
forward new torque 
value range 
A new torque value/forward new torque 
value is exceeded the torque limit setting 
value. 
(Note): When the individual setting is used 
for new torque value and reverse 
new torque value, it indicates 
outside forward new torque value.
The torque change is not carried out. 
 
 
 
 
 
 
 
114 
Below bias speed 
The command speed is below the bias 
speed at start. 
Operate by the bias speed at start. 
 
 
 
 
 
 
115 
Outside reverse new 
torque value range 
A reverse new torque value is exceeded 
the torque limit setting value. 
The torque change is not carried out.