Appendix - 28 
Appendices
 
Appendix 2 Connection with servo amplifiers 
 
SSCNET   cables are used to connect between Simple Motion module and servo 
amplifier or between servo amplifiers. 
Install the battery to servo amplifier to execute absolute position detection control.
 
Refer to each servo amplifier instruction manual for details. 
 
1)
SSCNET    Cable length
  When MR-J3BUS    M is used
  1)     3m (9.84ft.)
  When MR-J3BUS    M-A is used
  1)     20m (65.62ft.)
  When MR-J3BUS    M-B is used
  1)     50m (164.04ft.)
SSCNET    Cable length
  When MR-J3BUS _ M is used
  1)     3m (9.84ft.)
  When MR-J3BUS _ M-A is used
  1)     20m (65.62ft.)
  When MR-J3BUS _ M-B is used
  1)     50m (164.04ft.)
CN1A
CN1B
 (Note): It cannot communicate with that the connection of CN1A and CN1B is mistaken.
Cap
Servo amplifier
CN1A
CN1B
1)
Servo amplifier
QD77MS
SSCNET   connector
 
 
 
CAUTION
  Be sure to connect SSCNET   cable with the above connector. If the connection is mistaken, between 
the Simple Motion module and servo amplifier cannot be communicated. 
 SSCNET   connector to connect the SSCNET   cable is put a cap to protect light device inside 
connector from dust. For this reason, do not remove a cap until just before connecting SSCNET  
cable. Then, when removing SSCNET   cable, make sure to put a cap. 
  Keep the cap and the tube for protecting light cord end of SSCNET   cable in a plastic bag with a 
zipper of SSCNET   cable to prevent them from becoming dirty. 
  Do not remove the SSCNET   cable while turning on the power supply of Simple Motion module and 
servo amplifier. Do not see directly the light generated from SSCNET   connector of Simple Motion 
module or servo amplifier and the end of SSCNET   cable. When the light gets into eye, may feel 
something is wrong for eye. (The light source of SSCNET   cable complies with class1 defined in 
JISC6802 or IEC60825-1.) 
  When exchanging the Simple Motion module or servo amplifier, make sure to put a cap on SSCNET  
connector. When asking repair of Simple Motion module or servo amplifier for some troubles, make also 
sure to put a cap on SSCNET   connector. When the connector is not put a cap, the light device may 
be damaged at the transit. In this case, exchange and repair of light device is required.