4   AUXILIARY AND APPLIED FUNCTIONS 
 
4.5 Security Function 
This function is used to protect the user data of Motion CPU by registering a password. 
The illegal reading or writing of the user data are prevented by setting a password. 
Registered password can be changed and deleted. 
[Register/Change Password] or [Delete Password] screen is used to register/ 
change/delete a password. Select from a menu bar to display these screen.  
 
 
 
The user data protected in this function are shown below.  
"Write Protection" or "Read/Write Protection" can be set every user data. 
 
Operating 
system software 
User data 
Protected contents 
Motion SFC program 
Motion SFC programs (Control code, text)  
SV13/SV22 
Servo program 
Servo programs and program allocation  
Mechanical system program  Mechanical system programs  
SV22 
Cam data 
Cam data  
 
4.5.1 Password registration/change 
Select menu [Online]   [Register Password]   [Register/Change] to register/change a 
password. 
 
(1)   Procedure for password registration 
(a)   Enter initial registration password in password column, and select 
registration condition (Write Protection, Read/Write Protection). It leaves in 
blank for the user data that does not register a password. 
 
(b)   Click on [Execute] button to register a password in the Motion CPU. 
 
(c)   Select menu [Project]   [Save] to save a password after registration in a 
project.  
Refer to Section 4.5.4 for password save. 
 
(2)   Procedure for password change 
(a)   Status of password registered in the Motion CPU are displayed.