3 - 10 
3   COMMON PARAMETERS 
 
3.1.3 Individual parameters 
(1)   System basic setting 
The following explains each item to be set in system basic setting.  
 
 
 
(a)   Operation cycle 
1)   Set the of motion operation cycle (cycles at which a position command is 
computed and sent to the servo amplifier). 
The setting range is 0.4ms/0.8ms/1.7ms/3.5ms/7.1ms/14.2ms/Automatic 
setting. The actual operation cycle corresponding to 0.4ms is 0.444...ms. 
Similarly, 0.8ms corresponds to 0.888…ms, 1.7ms to 1.777...ms, 3.5ms 
to 3.555...ms, 7.1ms to 7.111...ms, and 14.2ms to 14.222…ms, 
respectively. 
 
2)   The default value is "Automatic Setting". When "Automatic Setting" is 
selected, the operation cycle is set according to the table below based 
on the number of axes for servo amplifier set in the System Settings. 
 
Operating system 
Number of axes 
Operation cycle setting 
1 to 6 axes 
0.4 ms 
7 to 18 axes 
0.8 ms 
SV13 
19 to 32 axes 
1.7 ms 
1 to 4 axes 
0.4 ms 
5 to 12 axes 
0.8 ms 
13 to 28 axes 
1.7 ms 
SV22 
29 to 32 axes 
3.5 ms