4 - 1 
4   AUXILIARY AND APPLIED FUNCTIONS 
 
 
 
 
 
 
 
 4 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
4. AUXILIARY AND APPLIED FUNCTIONS 
4.1 Limit Switch Output Function  
This function is used to output the ON/OFF signal corresponding to the data range of 
the watch data set per output device. 
Motion control data or optional word data can be used as watch data. (Refer to Section 
"4.1.2 Limit output setting data" for details.) A maximum output device for 32 points can 
be set regardless of the number of axes. 
 
4.1.1 Operations  
(1)   ON output to an output device is made while the watch data value is in the ON 
output region set with (ON Value) and (OFF Value) in this function.  
(a)   (ON Value), (OFF Value) and watch data value are handled as signed data.  
ON output region where an ON output is made to the output device is 
governed by the magnitude relationship between (ON Value) and (OFF 
Value) as indicated below.  
 
Relationship between (ON Value) and 
(OFF Value) 
ON output region  
(ON Value) < (OFF Value) 
(ON Value) <= (watch data value) < (OFF Value) 
(ON Value) > (OFF Value) 
(ON Value) <= (watch data value)  
(Watch data value) < (OFF Value)  
(ON Value) = (OFF Value) 
Output OFF in whole region 
 
1)  (ON Value) < (OFF Value)  
 
 Output device
 ON region setting
 Watch data value
OFF
OFF Value
ON Value
ON
OFF
(ON Value)   (Watch data value)   (OFF Value)
 
 
2)  (ON Value) > (OFF Value)  
 
ON Value
 Output device
 ON region setting
 Watch data value
OFF Value
ON
OFF
(Watch data value)   (OFF Value)
(ON Value)   (Watch data value)
ON