)XQFWLRQVRIWKH.H\SDGV
1. DISPLAY WINDOW.
Alpha Display Keypads:  2-line, 32-
character Liquid Crystal Display (LCD)
keypads that display protection point
identification, system status, and messages.
Fixed-Word Display Keypads: Display
protection zone ID and system status
messages using pre-designated words in the
LCD display.
2.
OFF
    
 Disarms burglary portion of the
system,  silences alarms and audible trouble
indicators, and  clears visual display after
problem's correction.
3.
AWAY
  
 Arms the entire burglary system,
perimeter and interior.
4.
STAY  
  
 Arms perimeter portion of burglary
system only. Interior protection is not armed,
allowing  movement within premises without
causing an alarm.
5.
5
  
TEST
  
   
Tests the system and alarm
sounder if  disarmed. Refer to Testing The
System
 section for test procedures.
6.
6
 BYPASS
 Removes individual protection
zones  from being monitored by the system.
7.
CHIME  
 
Turns CHIME mode on and off.
When  on, the opening of windows or doors
while the system is disarmed will sound 3
beeps at the keypad(s).
8.
    
#
 
  
 
 
 
This key can be used for "Quick
Arming" of the system without use of a
security code (if programmed).
9.
8 
CODE
   
 Used to assign additional user
codes for other users of the system.
10. KEYS 0–9: Used to enter your security
code(s) and to perform their associated
system functions after the security code has
been entered.
11.
INSTANT
 Arms in manner similar to the
STAY mode, but without the entry delay
feature. Entering via an entry/exit door will
cause an alarm.
12.
 
READY
 
 
Used to display all open protection
 zones.
13. FUNCTION KEYS: Keys A, B, C, D may
have been programmed for a variety of
functions, including panic (emergency)
functions. For details, see the Function Keys
section.
14.
MAXIMUM
   
Arms the entire burglary
system, perimeter and interior, but without
entry delay feature. Entering via an
entry/exit door will cause an alarm.
15. INTERNAL SOUNDER: The built-in
sounder mimics the alarm sounder during
alarms, and will also "beep" during certain
system functions.
16. READY INDICATOR: (GREEN) Lit when
the system is ready to be armed (no faults
present). While the system is disarmed, this
indicator will go on and off as protection
zones are closed and opened.
17. ARMED INDICATOR: (RED) Lit when the
system has been armed.