7 - 9 
7   OPERATION CONTROL PROGRAMS  
 
7.3 Constant Descriptions  
The constant descriptions of the 16-bit integer type, 32-bit integer type and 64-bit 
floating-point type are shown below.  
 
 
16-Bit integer type 
32-Bit integer type 
64-Bit floating-point type 
Decimal 
representation 
K-32768 to K32767 
K-2147483648L to K2147483647L 
K-1.79E+308 to K-2.23E-308,  
K0.0,  
K2.23E-308 to K1.79E+308 
Hexadecimal 
representation  
H0000 to HFFFF 
H00000000L to HFFFFFFFFL 
— 
 
(1)   The 32-bit integer type is ended by L and the 64-bit floating-point type is provided 
with a decimal point and exponent part (E) to denote their data types explicitly.  
 
(2)   The constant without the data type is regarded as the applicable minimum type.  
 
(3)   The constant in decimal representation is headed by K and the one in 
hexadecimal representation by H.  
K can be omitted.  
 
(4)   The 64-bit floating-point type cannot be represented in hexadecimal.