7 - 17 
7   OPERATION CONTROL PROGRAMS  
 
F/FS G 
 
 
7.4.6 Remainder : %  
Format 
(S1)%(S2) 
 
Number of basic steps 
 
[Usable data] 
 
Usable Data 
Word device 
Constant 
Setting 
data 
Bit device 
16-bit 
integer 
type 
32-bit 
integer 
type (L) 
64-bit 
floating 
point  
type (F) 
Coasting 
timer 
16-bit 
integer 
type (K/H) 
32-bit 
integer type 
(K/H, L) 
64-bit 
floating 
point  
type (K) 
Calculation 
expression 
Bit 
conditional 
expression
Comparison 
conditional 
expression 
(S1) — 
 
 
— 
 
 
 
— 
 
— — 
(S2) — 
 
 
— 
 
 
 
— 
 
— — 
 : Usable 
 
[Setting data] 
 
Setting data 
Description 
Data type of result 
(S1) Dividend 
data 
(S2) Divisor 
data 
Data type (integer type) of 
(S1) or (S2) which is greater 
(Integer type)  
 
[Functions] 
(1)   The data specified with (S1) is divided by the data specified with (S2) to find a 
remainder.  
 
(2)   When (S1) and (S2) differ in data type, the data of the smaller data type is 
converted into that of the greater type before operation is performed.  
 
[Errors] 
(1)   An operation error will occur if:  
•  (S2) is 0; or  
•  (S1) or (S2) is an indirectly specified device and its device No. is outside the 
range.  
 
[Program examples] 
(1)   Program which divides K456 by #0 and substitutes a remainder to W0  
 
W0 = K456 % #0  
 
 
#0 
123
 
W0 
87 
456