Справочник Пользователя для Mitsubishi Electronics Q172CPU(N)

Скачать
Страница из 472
 
 
 
7 - 44 
7   OPERATION CONTROL PROGRAMS  
 
F/FS G 
 
 
7.7.5 Signed 64-bit floating-point value conversion : FLOAT  
Format 
FLOAT(S) 
 
Number of basic steps 
 
[Usable data] 
 
Usable Data 
Word device 
Constant 
Setting 
data 
Bit device 
16-bit 
integer 
type 
32-bit 
integer 
type (L) 
64-bit 
floating 
point  
type (F) 
Coasting 
timer 
16-bit 
integer 
type (K/H) 
32-bit 
integer type 
(K/H, L) 
64-bit 
floating 
point  
type (K) 
Calculation 
expression 
Bit 
conditional 
expression
Comparison 
conditional 
expression 
(S) — 
 
 
 
 
 
 
 
 
— — 
 : Usable 
 
[Setting data] 
 
Setting data 
Description 
Data type of result 
(S) 
Data which will be converted into signed 64-bit 
floating-point value  
64-bit floating-point type  
 
[Functions] 
(1)   The data specified with (S) is converted into a signed 64-bit floating-point value.  
 
(2)   If (S) is a 64-bit floating-point type, its value is returned unchanged, with no 
conversion processing performed.  
 
[Errors] 
(1)   An operation error will occur if:  
•  (S) is an indirectly specified device and its device No. is outside the range.  
 
[Program examples] 
(1)   Program which converts the data of D0L into a signed 64-bit floating-point value 
and substitutes the result to #0F  
 
#0F = FLOAT(D0L)  
 
#3
#2
K-1.0
#1
#0
D1
K-1L
D0
(HFFFFFFFF)