Справочник Пользователя для Mitsubishi Electronics Q172CPU(N)

Скачать
Страница из 472
 
 
 
7 - 80 
7   OPERATION CONTROL PROGRAMS  
 
F/FS G 
 
 
7.13.5 Same data block transfer : FMOV  
Refer to the Section "1.3.4" for the correspondence version of the Motion CPU and the 
software. 
 
Format FMOV(D), 
(S), 
(n) 
 
Number of basic steps 
 
[Usable data] 
 
Usable Data 
Word device 
Constant 
Setting  
data 
Bit device 
16-bit 
integer 
type 
32-bit 
integer 
type (L) 
64-bit 
floating 
point  
type (F) 
Coasting 
timer 
16-bit 
integer 
type (K/H) 
32-bit 
integer type 
(K/H, L) 
64-bit 
floating 
point  
type (K) 
Calculation 
expression 
Bit 
conditional 
expression
Comparison 
conditional 
expression 
(D) 
 
 
— — — — 
 
— — — — 
(S) 
 
 
— — —   
— — — — — 
(n) — 
 
— — —   
— — — — — 
 : Usable 
 
[Setting data] 
 
Setting data 
Description 
Data type of result 
(D) 
Transfer destination device starting No. 
(S) 
Device No. which transfer data or data to be 
transferred are stored. 
(n) 
Number of words to be transferred  
— 
 
[Functions] 
(1)   The data specified with (S) or contents of word device are transferred a part for 
(n)words of data to the word device specified with (D).  
 
(2)   The word devices that may be set at (D), (S) and (n) are shown below.  
 
Word devices
(Note-1)
Bit devices
(Note-1), (Note-2)
 
Setting data  
Dn Wn #n Mn Bn  Fn  Xn  Yn 
(D) 
 
 
 
 
(Note-4)
 
 
 
(Note-3)
 
 
(Note-3)
 
(S) 
 
 
 
 
 
 
 
(Note-3)
 
 
(Note-3)
 
(n) 
 
 
 
— — — — — 
(Note-1) : The device No. cannot be specified indirectly. 
(Note-2) : Specify a multiple of 16 as the device number of bit data. 
(Note-3) : PX/PY cannot be set. 
(Note-4) : Special relays (M9000 to M9255) and dedicated devices (M2000 to M2399) cannot be set.