Справочник Пользователя для First Alert FA148CPSSIA

Скачать
Страница из 40
– 28 – 
 
 
 
 
01 Delete Zone?
 
0 = No  1 = Yes 
 
Deleting a Zone 
0 = don’t delete zones 
1 = go to next prompt to 
delete zones 
[
∗] to continue
 
To save the zone list, enter 0 and the system returns to the Zone 
List No. prompt. 
To delete a zone or zones in a zone list, enter 1 to continue.
 
 
 
 
01 Zn to Delete?
 
(00 = Quit) 
00 
 
Delete the Zone 
01-64† = zones to be 
deleted from list 
followed by [
∗] to 
accept each zone  
00 to continue
 
Enter each zone to be deleted from the list, followed by [
✱]. After 
all zones to be deleted are entered, enter 00 to return to the 
Zone List No. prompt so that another list can be programmed, if 
desired. 
† FA168CPS = 01-64; FA148CP = 01-06, 09-34, 49-56.
 
 
 
 
∗∗∗∗82 ALPHA DESCRIPTOR MENU MODE  
The system lets you assign zone descriptors for protection zones, keypad panics, and RF receiver supervision faults. Each 
description can be composed of a combination of up to 3 words selected from a vocabulary of words stored in memory (see 
Alpha Vocabulary List page). In addition, up to 10 installer-defined words can be added to those already in memory, plus 3 
additional words can be assigned as partition descriptors. Thus, when an alarm or trouble occurs in a zone, an appropriate 
description for that zone's location can be displayed at the keypad. Zone descriptors are recommended for systems using Alpha 
display keypads, and are necessary if a 4286 Phone Module is used. 
NOTE: You can also enter zone descriptors when the zone is being defined in 
✱56 Menu mode.  
 
4286 NOTE: If using a 4286 Phone Module, select from those words in the Alpha Vocabulary List shown in boldface type
The phone module will not provide annunciation of the other words. 
If a Phone Module is added to an existing system, the Alpha descriptors presently in the system should be reprogrammed, 
selecting from those words shown in boldface type in the Alpha Vocabulary List. The phone module will not provide 
annunciation of any other words.
 
 
 
∗∗∗∗82 Menu Mode 
 
 
 
P r o g r a m   A l p h a   ?  
0 = N o ,   1 = Y e s   0 0  
 
Program Alpha 
0 = no (quit Alpha mode) 
1 = yes 
[
∗] to continue 
The “Program Alpha ?” prompt will appear. Press 1 to continue.
 
 
 
 
C u s t o m   W o r d s   ?  
0 = N o ,   1 = Y e s   0 0  
 
Custom Words 
0 = no 
1 = yes 
 
The “Custom Words” prompt will appear. 
Press 0 to program standard alpha descriptors from the fixed 
vocabulary. The system then automatically displays the descriptor 
for zone 1. 
Press 1 to define custom words (see “Adding Custom Words”).
 
 
 
 
 
Z N   0 1  
 
 
 
Summary Screen 
[
∗] to continue to edit mode 
[#] = return to Program 
Alpha prompt (to quit) 
Note that this is a “Summary mode,” and that no entries can be 
made. Entries can be made only when the display contains a 
flashing cursor, which signifies Edit mode.” 
To exit the Alpha Descriptor mode, press 
∗ + 0 + 0 at the 
summary display.
 
 
 
 
 
Z N   0 1  
 
       
 
Edit Mode – Flashing 
Cursor 
 
to edit = zone number then 
[
∗], then zone 
number again 
 
6 = save word and go to 
next word in a 
descriptor  
 
8 = save descriptor and go 
to next zone
 
 
 [#] = return to Program 
Alpha prompt (to quit)
 
 
Descriptor screen for zone 1 appears. To program a descriptor 
(up to 3 words) for a zone, do the following: 
1. Enter the desired zone number (existing descriptor, if any, is 
displayed) and press [
∗], then enter the zone number again to 
start edit mode (flashing cursor appears). 
2. a. Press [#] plus the 3-digit number from the Alpha Vocabulary 
List for the first word. 
  b. Press [6] to accept the word and move the cursor for the next 
word in the descriptor. 
3. Repeat steps 2a and 2b for the second and third words (if used).
4. When all words for that descriptor have been entered, press [8] 
to save the descriptor for that zone. The summary screen 
displays for that zone and the flashing cursor disappears.  
5. Press [
∗] at the summary screen and repeat steps 1-4 to 
assign a descriptor for the next zone. 
6. When all descriptors have been entered, press [#]) at the last 
descriptor summary screen to return to the PROGRAM 
ALPHA? prompt. Enter 0 (no) at the prompt to exit this mode 
and return to Data Field mode.