Справочник Пользователя для First Alert FA148CPSSIA
– 39 –
WORKSHEET FOR SCHEDULES
(installer code + [#] + [6] [4];
master code can only access schedules 01-16 for FA168CPS, 01-04 for FA148CP, and events 00-07 for both
controls; FA148CP supports up to 8 schedules, FA168CPS supports up to 32 schedules
)
No.
Event
Device No.
Group No. Partition
Start Time/
Stop Time/
Repeat Random
(see list below)
for “01” events:
for “02” events: for “04-06” events:
Days Days
(1-4)
(yes/no)
enter 01-18
enter 1-8
enter 1, 2, or 3
01
02
03
04
05
06
07
08
09
10
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Events: Master/Installer
Events: Master/Installer
Installer
Only
00 = clear event
03 = latch key report
06 = auto disarm
10 = display custom words 8-10
01 = device on/off
04 = forced STAY arm
07 = display “reminder”
11 = periodic test report
02 = user access
05 = forced AWAY arm
Repeat Options: 0 = none; 1 = repeat weekly; 2 = repeat every other week; 3 = repeat every third week; 4 = repeat every fourth week
TABLE OF DEVICE ADDRESSES
This Device
Uses Address Reports as††
Enabled By…
RF Receiver
00
100
*56 zone programming: input device type entry
AUI 1
01
automatic if AUI enable field *189 enabled for AUI 1
AUI 2
02
automatic if AUI enable field *189 enabled for AUI 2
AUI 3
05
automatic if AUI enable field *189 enabled for AUI 3 (FA168CPS)
AUI 4
06
automatic if AUI enable field *189 enabled for AUI 4 (FA168CPS)
Communication Device (LRR)
03
103
automatic if communication device enabled in
∗29 Menu mode
4286 Voice Module
04
104
automatic if phone module access code field *28 enabled
Zone Expanders (4219/4229):
module 1 (for zones 09 - 16)
module 2 (for zones 17 - 24)
module 3 (for zones 25 - 32)
module 4 (for zones 33 - 40)
module 5 (for zones 41 - 48)
module 2 (for zones 17 - 24)
module 3 (for zones 25 - 32)
module 4 (for zones 33 - 40)
module 5 (for zones 41 - 48)
07
08
08
09
(FA168CPS)
10
(FA168CPS)
11
(FA168CPS)
107
108
109
110
111
108
109
110
111
*56 zone programming: input device type entry, then:
automatic if zone no. 9-16 entered as AW type or relay assigned
automatic if zone no. 17-24 entered as AW type or relay assigned
automatic if zone no. 25-32 entered as AW type or relay assigned
automatic if zone no. 33-40 entered as AW type or relay assigned
automatic if zone no. 41-48 entered as AW type or relay assigned
automatic if zone no. 17-24 entered as AW type or relay assigned
automatic if zone no. 25-32 entered as AW type or relay assigned
automatic if zone no. 33-40 entered as AW type or relay assigned
automatic if zone no. 41-48 entered as AW type or relay assigned
Relay Modules (4204):
module 1
module 2
module 3
module 4
module 2
module 3
module 4
12
13
13
14
(FA168CPS)
15
(FA168CPS)
112
113
114
115
113
114
115
*79 output device programming: device address prompt:
entered at device address prompt
entered at device address prompt
entered at device address prompt
entered at device address prompt
entered at device address prompt
entered at device address prompt
entered at device address prompt
Keypads:
keypad 1
keypad 2
keypad 3
keypad 4
keypad 5
keypad 6
keypad 7
keypad 8
keypad 2
keypad 3
keypad 4
keypad 5
keypad 6
keypad 7
keypad 8
16
17
18
19
20
21
22
23
17
18
19
20
21
22
23
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
data field programming as listed below:
always enabled, all sounds enabled.
data field *190
data field *191
data field *192
data field *193
data field *194
data field *195
data field *196
data field *190
data field *191
data field *192
data field *193
data field *194
data field *195
data field *196
5800TM Module
28
n/a
automatic
†† Addressable devices are identified by “1” plus
the device address when reporting. Enter report
code for zone 91 to enable addressable device
reporting (default = reports enabled). See field *19
for addressable device (ECP) 3-digit/2-digit
identification keypad display options.
the device address when reporting. Enter report
code for zone 91 to enable addressable device
reporting (default = reports enabled). See field *19
for addressable device (ECP) 3-digit/2-digit
identification keypad display options.