Справочник Пользователя для Mitsubishi Electronics QD77MS2

Скачать
Страница из 1038
 
 
5 - 22 
Chapter 5    Data Used for Positioning Control
 
5.2 List of parameters 
The setting items of the positioning parameter, OPR parameter or servo parameter are 
explained in this section. 
• Guide to buffer memory address 
In the buffer memory address, "n" in "1+150n", etc. indicates a value corresponding 
to axis No. such as the following table. 
 
Axis No. 
Axis No.
Axis No.
Axis No.
1 0 5 4 9 8 13 12 
2 1 6 5 10 9 14 13 
3 2 7 6 11 10 15 14 
4 3 8 7 12 11 16 15 
 
(Note-1): Calculate as follows for the buffer memory address corresponding to each axis. 
(Example) For axis No. 16 
1+150n ([Pr.4] Unit magnification (AM))=1+150 15=2251 
(Note-2): The range from axis No.1 to 2 (n=0 to 1) is valid in the QD77MS2. 
(Note-3): The range from axis No.1 to 4 (n=0 to 3) is valid in the QD77MS4. 
 
 
5.2.1 Basic parameters 1 
Item 
Setting value, setting range 
Default 
value 
Buffer memory address 
Value set with GX Works2 
Value set with sequence 
program 
QD77MS2 
QD77MS4 
QD77MS16
[Pr.1] Unit setting 
0 : mm 
3 0+150n 
1 : inch 
2 : degree 
3 : PLS 
M
ov
em
ent
 am
ount
 per pul
se 
[Pr.2]
 
Number of pulses per 
rotation (AP) 
(Unit : PLS) 
1 to 200000000 
1 to 200000000 
20000 
2+150n 
3+150n 
[Pr.3]
 
Movement amount per 
rotation (AL) 
The setting value range differs according to the "[Pr.1] Unit 
setting". 
20000 
4+150n 
5+150n 
[Pr.4]
 
Unit magnification (AM) 
1 : 1 times 
1 1+150n 
10 : 10 times 
10 
100 : 100 times 
100 
1000 : 1000 times 
1000 
[Pr.7]
 
Bias speed at start 
The setting value range differs according to the "[Pr.1] Unit 
setting". 
6+150n 
7+150n 
 
n: Axis No.-1