Справочник Пользователя для Mitsubishi Electronics QD77MS2

Скачать
Страница из 1038
 
 
5 - 40 
Chapter 5    Data Used for Positioning Control
 
5.2.4 Detailed parameters 2 
Item 
Setting value, setting range 
Default 
value 
Buffer memory address 
Value set with GX Works2 
Value set with sequence 
program 
QD77MS2 
QD77MS4 
QD77MS16
[Pr.25] Acceleration time 1 
1 to 8388608 (ms) 
1 to 8388608 (ms) 
1000 
36+150n 
37+150n 
[Pr.26] Acceleration time 2 
38+150n 
39+150n 
[Pr.27] Acceleration time 3 
40+150n 
41+150n 
[Pr.28] Deceleration time 1 
42+150n 
43+150n 
[Pr.29] Deceleration time 2 
44+150n 
45+150n 
[Pr.30] Deceleration time 3 
46+150n 
47+150n 
[Pr.31]
 
JOG speed limit value 
The setting range differs depending on the "[Pr.1] Unit setting".
20000 
48+150n 
49+150n 
[Pr.32]
 
JOG operation acceleration 
time selection 
0: [Pr.9] Acceleration time 0 
0 50+150n 
1: [Pr.25] Acceleration time 1 
2: [Pr.26] Acceleration time 2 
3: [Pr.27] Acceleration time 3 
[Pr.33]
 
JOG operation deceleration 
time selection 
0: [Pr.10] Deceleration time 0 
0 51+150n 
1: [Pr.28] Deceleration time 1 
2: [Pr.29] Deceleration time 2 
3: [Pr.30] Deceleration time 3 
[Pr.34]
 
Acceleration/deceleration 
process selection 
0 : Trapezoid acceleration/ 
deceleration process 
0 52+150n 
1 : S-curve acceleration/ 
deceleration process 
[Pr.35]
 
S-curve ratio 
1 to 100 (%) 
1 to 100 (%) 
100 
53+150n 
[Pr.36]
 
Sudden stop deceleration 
time 
1 to 8388608 (ms) 
1 to 8388608 (ms) 
1000 
54+150n 
55+150n 
[Pr.37]
 
Stop group 1 sudden stop 
selection 
0 : Normal deceleration stop 
56+150n 
[Pr.38]
 
Stop group 2 sudden stop 
selection 
57+150n 
1 : Sudden stop 
[Pr.39]
 
Stop group 3 sudden stop 
selection 
58+150n 
[Pr.40]
 
Positioning complete signal 
output time 
0 to 65535 (ms) 
0 to 65535 (ms) 
0 to 32767 
: Set as a 
decimal 
32768 to 65535 : Convert into 
hexadecimal 
and set 
300 59+150n 
 
n: Axis No.-1