Справочник Пользователя для Mitsubishi Electronics QD77MS2

Скачать
Страница из 1038
 
 
5 - 60 
Chapter 5    Data Used for Positioning Control
 
5.2.6 OPR detailed parameters 
 
Item 
Setting value, setting range 
Default 
value 
Buffer memory address 
Value set with GX Works2 
Value set with sequence 
program 
QD77MS2 
QD77MS4 
QD77MS16
[Pr.50]
 
Setting for the movement 
amount after near-point dog 
ON 
The setting value range differs depending on the "[Pr.1] Unit 
setting". 
80+150n 
81+150n 
[Pr.51]
 
OPR acceleration time 
selection 
0 : [Pr.9] Acceleration time 0 
0 82+150n 
1 : [Pr.25] Acceleration time 1 
2 : [Pr.26] Acceleration time 2 
3 : [Pr.27] Acceleration time 3 
[Pr.52]
 
OPR deceleration time 
selection 
0 : [Pr.10] Deceleration time 0 
0 83+150n 
1 : [Pr.28] Deceleration time 1 
2 : [Pr.29] Deceleration time 2 
3 : [Pr.30] Deceleration time 3 
[Pr.53]
 
OP shift amount 
The setting value range differs depending on the "[Pr.1] Unit 
setting". 
84+150n 
85+150n 
[Pr.54]
 
OPR torque limit value 
1 to 1000 (%) 
1 to 1000 (%) 
300 
86+150n 
[Pr.55]
 
Operation setting for 
incompletion of OPR
 
0 : Positioning control is not 
executed. 
0 87+150n 
1 : Positioning control is 
executed. 
[Pr.56]
 
Speed designation during 
OP shift 
0 : OPR speed 
0 88+150n 
1 : Creep speed 
[Pr.57]
 
Dwell time during OPR retry 
0 to 65535 (ms) 
0 to 65535 (ms) 
0 to 32767 
: Set as a 
decimal 
32768 to 65535 : Convert into 
hexadecimal 
and set 
0 89+150n 
 
n: Axis No.-1