Справочник Пользователя для Mitsubishi Electronics QD77MS2

Скачать
Страница из 1038
 
 
5 - 65 
Chapter 5    Data Used for Positioning Control
 
5.2.7 Expansion parameters 
Item 
Setting value, setting range 
Default value 
Buffer memory address 
Value set with GX Works2 
Value set with sequence 
program 
QD77MS2 
QD77MS4 
QD77MS16
[Pr.91]
 
Optional data monitor: 
Data type setting 1 
0  : No setting 
1  : Effective load ratio 
2  : Regenerative load ratio 
3  : Peak load factor 
4  : Load inertia moment ratio
5  : Model loop gain   
Position loop gain 
(Note-2) 
6  : Bus voltage
 
7  : Servo motor rotation speed
8  : Encoder multiple revolution 
counter 
9  : Module power 
consumption 
10 : Instantaneous torque 
12 : Servomotor thermistor 
temperature 
13 : Equivalent disturbance 
torque 
14 : Overload alarm margin 
15 : Error excessive alarm 
margin 
16 : Settling time 
17 : Overshoot amount 
20 : Position feedback 
(Note-1)
 
21 : Encoder single revolution 
position
 
(Note-1)
 
22 : Selection droop pulse   
 (Note-1) 
23 : Module integral power 
consumption
 (Note-1)
 
24 : Load side encoder 
information 1 
(Note-1)
 
25 : Load side encoder 
information 2 
(Note-1)
 
26 : Z-phase counter 
(Note-1)
 
27 : Servomotor-side/load-side 
position deviation 
(Note-1)
 
28 : Servomotor-side/load-side 
speed deviation 
(Note-1) 
29 : Encoder counter 
(Note-1)
 









10 
12 
13 
14 
15 
16 
17 
20 
21 
22 
23 
24 
25 
26 
27 
28 
0 100+150n 
[Pr.92]
 
Optional data monitor: 
Data type setting 2 
0 101+150n 
[Pr.93]
 
Optional data monitor: 
Data type setting 3 
0 102+150n 
[Pr.94]
 
Optional data monitor: 
Data type setting 4 
0 103+150n 
[Pr.96]
 
Operation cycle setting 
0: 0.88ms 
1: 1.77ms 

QD77MS2 : 0 
QD77MS4 : 0 
QD77MS16: 1 
147 
(Note-3)
 105 
(Note-3)
[Pr.97]
 
SSCNET setting 
0: SSCNET  
1: SSCNET /H 

106 
(Note-3)
 
[Pr.114]
 
External command signal 
compensation valid/invalid 
setting 
0: Invalid 
1: Valid 

114 
(Note-3)
 
 
n: Axis No. -1 
(Note-1): Used point: 2 words 
(Note-2): The name differs by MR-J4(W)-B/MR-JE-B/ 
MR-J3(W)-B or VCII series/FR-A700 series. 