5 - 70 
Chapter 5    Data Used for Positioning Control
 
5.2.8 Servo parameters   
(1)  Servo series  
 
Item 
Setting details 
Setting range 
Default  
value
Buffer memory address 
QD77MS2 
QD77MS4 
QD77MS16
[Pr.100] 
Servo 
series 
Used to select the servo amplifier series 
to connect to the Simple Motion module.
 
[POINT] 
• Be sure to set up servo series. 
Communication with servo amplifier isn't 
started by the initial value "0" in default 
value.  
(The LED indication of servo amplifier 
indicates "Ab".) 
• The connectable servo amplifier differs 
by the setting of "[Pr.97] SSCNET 
setting". 
0: Servo series is not set 
1: MR-J3-_B 
MR-J3W-_B (2-axis type) 
3: MR-J3-_B-RJ006   
(For fully closed loop control) 
MR-J3-_BS (For safety servo)
4: MR-J3-_B-RJ004 
(For linear servo) 
6: MR-J3-_B-RJ080W   
(For direct drive motor) 
32: MR-J4-_B 
MR-J4W-_B (2-axis type and 
3-axis type) 
48: MR-JE-_B 
64: FR-A700 series (Inverter) 
96: VCII series (manufactured by 
Nikki Denso Co., Ltd.)   
4097: Virtual servo amplifier 
(MR-J3) 
4128: Virtual servo amplifier   
(MR-J4) 
0 30100+200n 
28400+100n
 
n: Axis No. -1 
 
(2)  Parameters of MR-J4(W)-B/MR-JE-B 
The parameter list for MR-J4(W)-B/MR-JE-B is shown below. 
Refer to each servo amplifier instruction manual for details of setting items. 
Do not change other than the buffer memory addresses of the parameters 
described in each servo amplifier instruction manual. 
 
 
POINT 
 
Set the parameter value and switch power off once (The parameter is transferred to 
servo amplifier from Simple Motion module), and then switch it on again to make 
that parameter setting valid.