Справочник Пользователя для Mitsubishi Electronics QD77MS2

Скачать
Страница из 1038
 
 
5 - 116 
Chapter 5    Data Used for Positioning Control
 
5.6 List of monitor data 
The setting items of the monitor data are explained in this section. 
• Guide to buffer memory address 
In the buffer memory address, "n" in "2406+100n", etc. indicates a value 
corresponding to axis No. such as the following table. 
 
Axis No. 
Axis No.
Axis No.
Axis No.
1 0 5 4 9 8 13 12 
2 1 6 5 10 9 14 13 
3 2 7 6 11 10 15 14 
4 3 8 7 12 11 16 15 
 
(Note-1): Calculate as follows for the buffer memory address corresponding to each axis. 
(Example) For axis No. 16 
2406+100n ([Md.23] Axis error No.)=2406+100 15=3906 
(Note-2): The range from axis No.1 to 2 (n=0 to 1) is valid in the QD77MS2. 
(Note-3): The range from axis No.1 to 4 (n=0 to 3) is valid in the QD77MS4. 
 
5.6.1 System monitor data 
Storage item 
Storage details 
 
 
 
 
 
[Md.1] In test mode flag 
Whether the mode is the test mode from the GX Works2 or not is stored. 
 When not in test mode  : OFF 
 When in test mode 
: ON 
 
Refresh cycle: Immediate