Chapter 6    Sequence Program Used for Positioning Control
 
6.1 Precautions for creating program 
The common precautions to be taken when writing data from the PLC CPU to the 
buffer memory of Simple Motion module are described below. 
When diverting any of the program examples introduced in this manual to the actual 
system, fully verify that there are no problems in the controllability of the target system. 
 
(1)    Reading/writing the data 
Setting the data explained in this chapter (various parameters, positioning data, 
block start data) should be set using GX Works2. 
When set with the sequence program, many sequence programs and devices 
must be used. This will not only complicate the program, but will also increase 
the scan time. 
When rewriting the positioning data during continuous path control or continuous 
positioning control, rewrite the data four positioning data items before the actual 
execution. If the positioning data is not rewritten before the positioning data four 
items earlier is executed, the process will be carried out as if the data was not 
rewritten. 
 
(2)    Restrictions to speed change execution interval 
Provide an interval of 100ms or more when changing the speed or performing 
override function with the Simple Motion module. 
 
(3)  Process during overrun 
Overrun is prevented by the setting of the upper and lower stroke limits with the 
detailed parameter 1. 
However, this applies only when the Simple Motion module is operating correctly. 
It is recommended to create an external circuit including a boundary limit switch 
to ensure the whole system safety as follows: the external circuit that turns OFF 
the main circuit power of the servo amplifier when the boundary limit switch 
operates.