Справочник Пользователя для Mitsubishi Electronics QD77MS2

Скачать
Страница из 1038
 
 
6 - 70 
Chapter 6    Sequence Program Used for Positioning Control
 
6.5.5 Restart program 
When a stop factor occurs during position control and the operation stops, the 
positioning can be restarted from the stopped position to the position control end point 
by using the "restart command" ([Cd.6] Restart command). 
("Restarting" is not possible when "continuous operation is interrupted.") 
This instruction is efficient when performing the remaining positioning from the stopped 
position in the positioning control of incremental method such as INC linear 1. 
(Calculation of remaining distance is not required.) 
 
[1]  Restart operation 
After a deceleration stop by the stop command is completed, write "1: Restarts" 
to the "[Cd.6] Restart command" with "[Md.26] Axis operation status" is "stopped" 
and the positioning restarts. 
 
V
t
Start
Positioning data No.10
Positioning data No.11
Positioning data No.12
Stop process with
stop command
Positioning data No.11
continues with restart command
 
 
Fig. 6.13 Restart operation 
 
[2]  Restrictions 
 
(1)  Restarting can be executed only when the "[Md.26] Axis operation status" is 
"stopped (the deceleration stop by stop command is completed)". 
If the axis operation is not "stopped", restarting is not possible. 
In this case, the warning "Restart not possible" (warning code: 104) will occur, 
and the process at that time will be continued. 
(2)  Do not execute restart while the stop command is ON. 
If restart is executed while stopped, the error "Stop signal ON at start" (error 
code: 106) will occur, and the "[Md.26] Axis operation status" will change to 
"Error".  
Thus, even if the error is reset, the operation cannot be restarted. 
(3)  Restarting can be executed even while the positioning start signal is ON. 
However, make sure that the positioning start signal does not change from OFF 
to ON while stopped. 
(4)  If the positioning start signal is changed from OFF to ON while "[Md.26] Axis 
operation status" is "stopped", the normal positioning (the positioning data set in 
"[Cd.3] Positioning start No.") is started. 
(5)  If positioning is ended with the continuous operation interrupt request, the 
operation cannot be restarted. 
If restart is requested, the warning "Restart not possible" (warning code: 104) 
will occur.