8 - 6 
Chapter 8  OPR Control 
 
8.2.2 Machine OPR method 
The method by which the machine OP is established (method for judging the OP 
position and machine OPR completion) is designated in the machine OPR according 
to the configuration and application of the positioning method.   
The following table shows the methods that can be used for this OPR method. 
(The OPR method is one of the items set in the OPR parameters. It is set in "[Pr.43] 
OPR method" of the basic parameters for OPR.) 
 
[Pr.43] OPR method 
Operation details 
Near-point dog method 
Deceleration starts by the OFF 
  ON of the near-point dog. (Speed is reduced to "[Pr.47] 
Creep speed".) 
The operation stops once after the near-point dog turns ON and then OFF. Later the 
operation restarts and then stops at the first zero signal to complete the OPR. 
Count method 1) 
The deceleration starts by the OFF 
  ON of the near-point dog, and the machine moves 
at the "[Pr.47] Creep speed". 
The machine stops once after moving the distance set in the "[Pr.50] Setting for the 
movement amount after near-point dog ON" from the OFF 
  ON position. Later the 
operation restarts and then stops at the first zero point to complete the machine OPR. 
Count method 2) 
The deceleration starts by the OFF 
  ON of the near-point dog, and the machine moves 
at the "[Pr.47] Creep speed.   
The machine moves the distance set in the "[Pr.50] Setting for the movement amount after 
near-point dog ON" from the near-point dog OFF 
  ON position, and stops at that 
position. The machine OPR is then regarded as completed. 
Data set method 
The position where the machine OPR has been performed becomes an OP. 
The current feed value and feed machine value are overwritten to the OP address. 
Scale origin signal 
detection method 
The machine moves in the opposite direction against of "[Pr.44] OPR direction" at the 
"[Pr.46] OPR speed" by the OFF 
  ON of the near-point dog, and a deceleration stop is 
carried out once at the first zero signal. Later the operation moves in direction of "[Pr.44] 
OPR direction" at the "[Pr.47] Creep speed", and then stops at the detected nearest zero 
point to complete the machine OPR. 
 
REMARK 
Creep speed 
The stopping accuracy is poor when the machine suddenly stops from fast speeds. 
To improve the machine's stopping accuracy, it is required to slow down the 
speed before it stops. This speed is set in the "[Pr.47] Creep speed". 
 
The following shows the signals as required for machine OPR. 
 
[Pr.43] OPR method 
Signals required for control 
Near-point dog 
Zero signal 
Upper/lower limit 
Near-point dog method 
 
 
 
Count method 1) 
 
 
 
Count method 2) 
 
 
 
Data set method 
 
 
 
Scale origin signal detection method 
 
 
 
: Necessary,    : Necessary as required,   
: Unnecessary