9 - 49 
Chapter 9    Major Positioning Control 
 
9.2.6 1-axis fixed-feed control 
In "1-axis fixed-feed control" ("[Da.2] Control system" = fixed-feed 1), one motor is 
used to carry out fixed-feed control in a set axis direction.   
In fixed-feed control, any remainder of below control accuracy is rounded down to 
convert the movement amount designated in the positioning data into the command 
value to servo amplifier.   
 
 Operation chart 
 
In 1-axis fixed-feed control, the address ([Md.20] Current feed value) of the current 
stop position (start point address) is set to "0". Positioning is then carried out to a 
position at the end of the movement amount set in "[Da.6] Positioning address/ 
movement amount".   
The movement direction is determined by the movement amount sign. 
 
• Positive movement amount .............. Positioning control to forward direction 
(Address increase direction) 
• Negative movement amount ............. Positioning control to reverse direction 
(Address decrease direction) 
 
0
0
0
0
0
" Md. 20  Current feed 
value" is set to "0" at 
the positioning start
Designated 
movement 
amount
Positioning
start 
Reverse direction
Forward direction
Stop position
Movement direction for
a negative movement amount
Movement direction for
a positive movement amount
 
 
 Restrictions 
 
(1)  The error "Continuous path control not possible" (error code: 516) will occur 
and the operation cannot start if "continuous path control" is set in "[Da.1] 
Operation pattern". ("Continuous path control" cannot be set in fixed-feed 
control.) 
(2)  "Fixed-feed" cannot be set in "[Da.2] Control system" in the positioning data 
when "continuous path control" has been set in "[Da.1] Operation pattern" of 
the immediately prior positioning data. (For example, if the operation pattern of 
positioning data No. 1 is "continuous path control", fixed-feed control cannot 
be set in positioning data No. 2.) The error "Continuous path control not 
possible" (error code: 516) will occur and the machine will carry out a 
deceleration stop if this type of setting is carried out.