Chapter 1    Product Outline
 
1.2.2 Outline of starting 
The outline for starting each control is shown with the following flowchart. 
(It is assumed that each module is installed, and the required system configuration, 
etc., has been prepared.) 
 
Flow of starting
Preparation
Major positioning
control
Control 
functions
Installation and connection of module
Setting of hardware
Positioning
data
Block start
data 
Positioning 
parameters
OPR 
parameters
Servo 
parameters
PLC READY
All axis
servo ON 
Expansion
parameters
Start signal
Control start
Control end
Control data
High-level positioning
control
OPR control
Manual control
Position control
Speed control
Speed-position
switching control
Position-speed
switching control
Other control
Block start (Normal start)
Condition start
Wait start
Simultaneous start
Repeated start
Machine OPR control
Fast OPR control
JOG operation
Inching operation
Manual pulse generator
operation
Turn the All axis servo ON signal ON (Y1 ON)
Turn the PLC READY signal ON (Y0 ON)
Pr.100
Set the servo parameters.  (             , PA, PB, PC, PD, PE, PS, PF, Po, PL) 
Set the expansion parameters.  (              to              ,              ,              ,               ) 
Pr.91
Pr.94
Pr.96
(              to              ,              to             )
Da.1
Da.10
Da.20
Da.22
Set the positioning data. 
Set the block start data. 
(              to              ,              to             )
Da.11
Da.19
Da.23
Da.26
Operation
Stop
Operate the 
manual pulse 
generator
Turn the QD77MS JOG
start signal ON from the 
PLC CPU
Input the start signal.
  Method (1) Turn ON the QD77MS start signal from the PLC CPU
  Method (2) Issue the ZP.PSTRT instruction from the PLC CPU.
  Method (3) Turn the QD77MS external command signal ON
Cd.3
Set the positioning start No. (             )
(             )
Cd.4
Set the positioning starting point No.
(             )
Cd.17
Set the JOG speed.
Set "0" to the inching 
movement amount.
(             )
Cd.16
Set a value except "0" to the 
inching movement amount.
(             )
Cd.16
Set "1" to the manual pulse 
generator enable flag.
(             )
Cd.21
Set the manual pulse generator
1 pulse input magnification.
(             )
Cd.20
Set the positioning parameters.  (              to              ,               to              ,               ,              ,               ) 
Pr.1
Pr.42
Pr.84
Pr.80
Pr.89
Pr.90
Pr.95
Set the OPR parameters. 
(              to              ,               ,              )
Pr.86
Pr.87
Pr.43
Pr.57
Pr.97
Pr.114