10 - 8 
Chapter 10  High-Level Positioning Control 
 
10.3.2 Block start (normal start) 
In a "block start (normal start)", the positioning data groups of a block starting from the 
positioning data set in "[Da.12]Start data No." are continuously executed with the set 
order by starting once.. 
 
Section [2] shows a control example where the "block start data" and "positioning data" 
are set as shown in section [1].   
 
[1]  Setting examples 
 
(1)    Block start data setting example 
 
Axis 1 block 
start data 
[Da.11] 
Shape 
[Da.12] 
Start data No.
[Da.13] 
Special start 
instruction 
[Da.14] 
Parameter 
1st point 
1: Continue 
0: Block start 
– 
2nd point 
1: Continue 
0: Block start 
– 
3rd point 
1: Continue 
0: Block start 
– 
4th point 
1: Continue 
10 
0: Block start 
– 
5th point 
0: End 
15 
0: Block start 
– 
 
 
 
 
 
 
 
 
 
 
 
(2)    Positioning data setting example 
 
Axis 1 positioning 
data No. 
[Da.1] 
Operation pattern 
 
 
1 00: 
Positioning 
complete   
 
11: Continuous path control 
1 block 
(Note-1)
1 block
 
01: Continuous positioning control
4 00: 
Positioning 
complete 
11: Continuous path control 
6 00: 
Positioning 
complete 
 
 
 
 
10 00: 
Positioning 
complete   
 
 
 
 
 
15 00: 
Positioning 
complete   
 
 
 
 
 
 
REMARK 
(Note-1): Block 
"1 block" is defined as all the data continuing from the positioning data in 
which "continuous positioning control" or "continuous path control" is set in 
the "[Da.1] Operation pattern" to the positioning data in which "independent 
positioning control (Positioning complete)" is set.