Chapter 11    Manual Control
 
11.3.3 Setting the required parameters for inching operation 
The "Positioning parameters" must be set to carry out inching operation. 
The following table shows the setting items of the required parameters for carrying out 
inching operation. Parameters not shown below are not required to be set for carrying 
out only inching operation. (Set the initial value or a value within the setting range.) 
 
Setting item 
Setting requirement
Factory-set initial value 
(setting details) 
Positioning para
m
eters
 
[Pr.1] 
Unit setting 
3 (PLS) 
[Pr.2] 
Number of pulses per rotation (AP) (Unit: PLS) 
20000 
[Pr.3] 
Movement amount per rotation (AL) (Unit: PLS) 
20000 
[Pr.4] 
Unit magnification (AM) 
1 (1 times) 
[Pr.11]  Backlash compensation amount (Unit: PLS) 
[Pr.12]  Software stroke limit upper limit value (Unit: PLS) 
2147483647 
[Pr.13]  Software stroke limit lower limit value (Unit: PLS) 
–2147483648 
[Pr.14]  Software stroke limit selection 
0 (current feed value) 
[Pr.15]  Software stroke limit valid/invalid setting 
0 (valid) 
[Pr.17]  Torque limit setting value (Unit: %) 
300 
[Pr.31]  JOG speed limit value (Unit: PLS/s) 
20000 
 
  :  Setting always required.   
  :  Set according to requirements (Set the initial value or a value within the setting range when not used.)   
 
REMARK 
 Positioning parameter settings work in common for all controls using the Simple 
Motion module. When carrying out other controls ("major positioning control", 
"high-level positioning control", and "OPR control"), set the respective setting items 
as well. 
 Parameters are set for each axis. 
 Refer to Chapter 5 "Data Used for Positioning Control" for the setting details.