11.4 Manual pulse generator operation 
11.4.1 Outline of manual pulse generator operation 
  Manual pulse generator operation 
 
In manual pulse generator operations, pulses are input to the Simple Motion 
module from the manual pulse generator. This causes the same number of input 
command to be output from the Simple Motion module to the servo amplifier, and 
the workpiece is moved in the designated direction.   
The following shows an example of manual pulse generator operation.   
 
1)
When "[Cd.21] Manual pulse generator enable flag" is set to "1", the BUSY signal turns 
ON and the manual pulse generator operation is enabled. 
2)
The workpiece is moved corresponding to the number of pulses input from the manual 
pulse generator. 
3)
The workpiece movement stops when no more pulses are input from the manual pulse 
generator. 
4)
When "[Cd.21] Manual pulse generator enable flag" is set to "0", the BUSY signal turns 
OFF and the manual pulse generator operation is disabled. 
 
 
[QD77MS4 operation example] 
Manual pulse 
generator 
operation stops
t
BUSY signal  [XC, XD, YE, XF]
Manual pulse 
generator input
Start complete signal
                [X10, X11, X12, X13]  
Manual pulse generator operation enabled
0
OFF
ON
OFF
1) 2)
3)
4)
1
0
Cd. 21 Manual pulse
generator enable flag
1
2
 
 
(Note): Refer to Section 3.3 for input/output signal of QD77MS16.
 
[Precautions] 
1:  If the input from the manual pulse generator stops, the machine will decelerate to a stop within 25 ms.   
2:  The start complete signal does not turn ON in manual pulse generator operation. 
 
Fig. 11.16 Manual pulse generator operation 
 
Important 
 
Create the sequence program so that "[Cd.21] Manual pulse generator enable flag" 
is always set to "0" (disabled) when a manual pulse generator operation is not 
carried out. 
Mistakenly touching the manual pulse generator when the "manual pulse generator 
enable flag" is set to "1" (enable) can cause accidents or incorrect positioning.