13 - 8 
Chapter 13  Control Sub Functions
 
13.2.2 OP shift function   
When a machine OPR is carried out, the OP is normally established using the near-
point dog or zero signal. However, by using the OP shift function, the machine can be 
moved a designated movement amount from the position where the zero signal was 
detected. A mechanically established OP can then be interpreted at that point.   
 
The details shown below explain about the "OP shift function".   
 [1] Control details 
  [2] Setting range for the OP shift amount   
  [3] Movement speed during OP shift 
  [4] Precautions during control 
  [5] Setting the OP shift function 
 
[1]  Control details 
The following drawing shows the operation of the OP shift function.   
 
Machine OPR start 
Pr.53 OP shift amount 
Speed selected by the" Pr. 56
Speed designation during
OP shift"
Pr.47  Creep speed
Pr. 44  OPR direction 
Near-point dog
Pr. 46 OPR speed 
Zero signal 
 
Fig. 13.4 OP shift operation