Справочник Пользователя для Mitsubishi Electronics QD77MS2

Скачать
Страница из 1038
 
 
13 - 67 
Chapter 13  Control Sub Functions
 
13.7 Other functions 
Other functions include the "step function", "skip function", "M code output function", 
"teaching function", "command in-position function", "acceleration/deceleration 
processing function", "pre-reading start function", "deceleration start flag function", 
"stop command processing for deceleration stop function", "follow up processing 
function", "speed control 10    multiplier setting for degree axis function" and 
"operation setting for incompletion of OPR function". Each function is executed by 
parameter setting or sequence program creation and writing.   
 
13.7.1 Step function 
The "step function" is used to confirm each operation of the positioning control one by 
one.  
It is used in debugging work for major positioning control, etc. 
A positioning operation in which a "step function" is used is called a "step operation".   
In step operations, the timing for stopping the control can be set. (This is called the 
"step mode".) Control stopped by a step operation can be continued by setting "step 
continues (to continue the control)" in the "step start information".   
 
The details shown below explain about the "step function".   
  [1] Relation between the step function and various controls 
 [2] Step mode 
  [3] Step start information 
  [4] Using the step operation   
 [5] Control details 
  [6] Precautions during control 
  [7] Step function settings 
 
[1]    Relation between the step function and various controls 
The following table shows the relation between the "step function" and various 
controls. 
 
Control type 
Step function
Step applicability 
OPR control 
Machine OPR control 
Step operation not possible
Fast OPR control 
Major positioning 
control 
Position 
control 
1-axis linear control 
Step operation possible 
2 to 4-axes linear interpolation control 
1-axis fixed-feed control 
2 to 4- axes fixed-feed control 
(interpolation) 
 
2-axis circular interpolation control 
1 to 4- axes Speed control 
Step operation not possible
Speed-position switching control 
Position-speed switching control 
 
Step operation possible 
Other 
control 
Current value changing 
JUMP instruction, NOP instruction, 
LOOP to LEND 
 
Step operation not possible
Manual control 
JOG operation, Inching operation 
Step operation not possible
Manual pulse generator operation 
Expansion 
control 
Speed-torque control 
 
 
               
: Set when required, 