Chapter 13  Control Sub Functions
 
13.7.11 Operation setting for incompletion of OPR function 
The "Operation setting for incompletion of OPR function" is provided to select whether 
positioning control is operated or not, when OPR request flag is ON. 
 
This section explains the "Operation setting for incompletion of OPR function" as 
follows: 
 [1] Control details 
  [2] Precautions during control 
  [3] Setting method of "Operation setting for incompletion of OPR function" 
 
[1]  Control details 
 
When "[Pr.55] Operation setting for incompletion of OPR" is valid, this function 
related to the command speed, monitor data, speed limit value, is shown below. 
 
Item 
[Pr.55] Operation setting for incompletion of OPR 
"0: Positioning control is not 
executed." and   
"OPR request flag ON" 
"1: Positioning control is 
executed." and   
"OPR request flag ON" 
 
 
Machine OPR 
 
 
JOG operation 
 
 
Inching operation 
 
 
Manual pulse generator operation 
 
 
Current value changing using current 
value changing start No. (No. 9003).
 
 
When the following cases at block start, 
condition start, wait start, repeated start, 
multiple axes simultaneous start 
and pre-reading start. 
 
 
1-axis linear control 
 
 
2/3/4-axis linear interpolation control
 
  1/2/3/4-axis fixed-feed control 
 
  2-axis circular interpolation control 
(with sub point designation/center 
point designation) 
 
  1/2/3/4-axis speed control 
 
 Speed-position switching control  
(INC mode/ ABS mode) 
 
  Position-speed switching control 
 
 
Current value changing using 
positioning data No. (No.1 to 600). 
 
 
Control mode switching 
 
: Positioning start possible (Execution possible) 
: Positioning start impossible (Execution not possible) 
 
[2]  Precautions during control 
 
(1) The error "Start at OPR incomplete" (error code: 547) occurs if OPR request 
flag ([Md.31] Status: b3) is executed the positioning control by turning on, 
when "0: Positioning control is not executed" is selected the operation setting 
for incompletion of OPR setting, and positioning control will not be performed. 
At this time, operation with the manual control (JOG operation, inching 
operation, manual pulse generator operation) is available.