Справочник Пользователя для Mitsubishi Electronics QD77MS2

Скачать
Страница из 1038
 
 
14 - 56 
Chapter 14  Common Functions
 
14.12 Module error collection function   
This function collects errors occurred in the Simple Motion module in the PLC CPU. 
Those errors are stored in a memory (latch area) of the PLC CPU as module error logs. 
The stored error logs are retained even when the PLC CPU is powered off or reset. 
 
Time
Module in error
Error code
QD77MS
QD77MS
Module B
19:29
19:36
19:34
Error A1
Error B1
Error A2
GX Works2
3)
Error history display
Time
Module in error
Error code
QD77MS
QD77MS
CPU
Module B
19:29
19:34
19:36
19:33
Error A1
Error C1
Error B1
Error A2
Error history of PLC CPU and intelligent function 
module is displayed in one screen.
Errors in the entire system can be monitored in reverse
chronological order.
1)
CPU
Module error log
19:33 Error C1
Error history
(CPU module)
2)
<Operation>
1) The error occurs in the PLC CPU or Intelligent function module.
2) The PLC CPU collects and stores the error in each intelligent function
    module as "Module error history".
3) The list of error in PLC CPU or each intelligent function module error is
    displayed  with GX Works2.
19:33 Error C1 occurred!
QD77MS
19:29 Error A1 occurred!
19:36 Error A2 occurred!
Module B
19:34 Error B1 occurred!
 
 
For details on the module error collection function, refer to Section 16.1 "Checking 
errors using GX Works2".